Your browser doesn't support javascript.
loading
In vivo sun protection factor and UVA protection factor determination using (hybrid) diffuse reflectance spectroscopy and a multi-lambda-LED light source.
Throm, Carolin Maria; Wiora, Georg; Reble, Carina; Schleusener, Johannes; Schanzer, Sabine; Karrer, Hans; Kolbe, Ludger; Khazaka, Georg; Meinke, Martina C; Lademann, Jürgen.
Afiliação
  • Throm CM; Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Dermatology, Venereology and Allergology, Berlin, Germany.
  • Wiora G; Courage+Khazaka electronic GmbH, Cologne, Germany.
  • Reble C; Courage+Khazaka electronic GmbH, Cologne, Germany.
  • Schleusener J; Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Dermatology, Venereology and Allergology, Berlin, Germany.
  • Schanzer S; Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Dermatology, Venereology and Allergology, Berlin, Germany.
  • Karrer H; Hans Karrer GmbH, Augsburg, Germany.
  • Kolbe L; Beiersdorf AG, Research and Development, Hamburg, Germany.
  • Khazaka G; Courage+Khazaka electronic GmbH, Cologne, Germany.
  • Meinke MC; Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Dermatology, Venereology and Allergology, Berlin, Germany.
  • Lademann J; Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Dermatology, Venereology and Allergology, Berlin, Germany.
J Biophotonics ; 14(2): e202000348, 2021 02.
Article em En | MEDLINE | ID: mdl-33025740
The sun protection factor (SPF) values are currently determined using an invasive procedure, in which the volunteers are irradiated with ultraviolet (UV) light. Non-invasive approaches based on hybrid diffuse reflectance spectroscopy (HDRS) have shown a good correlation with conventional SPF testing. Here, we present a novel compact and adjustable DRS test system. The in vivo measurements were performed using a multi-lambda-LED light source and an 84-channel imaging spectrograph with a fiber optic probe for detection. A transmission spectrum was calculated based on the reflectance measured with sunscreen and the reflectance measured without sunscreen. The preexposure in vitro spectrum was fitted to the in vivo spectrum. Each of the 11 test products was investigated on 10 volunteers. The SPF and UVA-PF values obtained by this new approach were compared with in vivo SPF results determined by certified test institutes. A correlation coefficient R2 = 0.86 for SPF, and R2 = 0.92 for UVA-PF were calculated. Having examined various approaches to apply the HDRS principle, the method we present was found to produce valid and reproducible results, suggesting that the multi-lambda-LED device is suitable for in-vivo SPF testing based on the HDRS principle as well as for in-vivo UVA-PF measurements.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Protetores Solares / Fator de Proteção Solar Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Protetores Solares / Fator de Proteção Solar Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article