Your browser doesn't support javascript.
loading
Determination of p53 biomarker using an electrochemical immunoassay based on layer-by-layer films with NiFe2O4 nanoparticles.
Ibáñez-Redín, Gisela; Joshi, Nirav; do Nascimento, Gustavo Freitas; Wilson, Deivy; Melendez, Matias E; Carvalho, André L; Reis, Rui Manuel; Gonçalves, Débora; Oliveira, Osvaldo N.
Afiliação
  • Ibáñez-Redín G; São Carlos Institute of Physics, University of São Paulo, SP, 13560-970, São Carlos, Brazil.
  • Joshi N; São Carlos Institute of Physics, University of São Paulo, SP, 13560-970, São Carlos, Brazil. nirav.joshi1986@gmail.com.
  • do Nascimento GF; São Carlos Institute of Physics, University of São Paulo, SP, 13560-970, São Carlos, Brazil.
  • Wilson D; São Carlos Institute of Physics, University of São Paulo, SP, 13560-970, São Carlos, Brazil.
  • Melendez ME; Pelé Little Prince Research Institute, Little Prince Complex, PR, 80250-060, Curitiba, Brazil.
  • Carvalho AL; Molecular Oncology Research Center, Barretos Cancer Hospital, SP, 14784-400, Barretos, Brazil.
  • Reis RM; Molecular Oncology Research Center, Barretos Cancer Hospital, SP, 14784-400, Barretos, Brazil.
  • Gonçalves D; Molecular Oncology Research Center, Barretos Cancer Hospital, SP, 14784-400, Barretos, Brazil.
  • Oliveira ON; Life and eHealth Sciences Research Institute (ICVS), Medical School, University ofMinho, Braga, Portugal.
Mikrochim Acta ; 187(11): 619, 2020 10 21.
Article em En | MEDLINE | ID: mdl-33083850
ABSTRACT
A disposable electrochemical immunosensors is presented suitable to detect cancer biomarker p53 using screen-printed carbon electrodes modified with a layer-by-layer (LbL) matrix of carboxylated NiFe2O4 nanoparticles and polyethyleneimine, onto which anti-p53 antibodies were adsorbed. Under optimized conditions, the immunosensors exhibited high surface coverage and high concentration of immobilized antibodies, which allowed for detection of p53 in a wide dynamic range from 1.0 to 10 × 103 pg mL-1, with a limit of detection of 5.0 fg mL-1 at a working potential of 100 mV vs. Ag/AgCl. The immunosensors also exhibited good selectivity with negligible interference upon incubation in complex matrices containing high concentrations of proteins (i.e., fetal bovine serum and cell lysate). The immunosensor performance is among the best reported in the literature for determination of p53, with the additional advantage of being disposable and operating with low-volume solutions.Graphical abstract Schematic representation of immunosensor fabrication depicting the immobilization of specific antibodies against p53 protein onto the surfaces of disposable printed electrodes modified with films of polyethyleneimine and different concentrations of carboxylated magnetic nanoparticles.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imunoensaio / Compostos Férricos / Biomarcadores Tumorais / Proteína Supressora de Tumor p53 / Técnicas Eletroquímicas / Níquel Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imunoensaio / Compostos Férricos / Biomarcadores Tumorais / Proteína Supressora de Tumor p53 / Técnicas Eletroquímicas / Níquel Idioma: En Ano de publicação: 2020 Tipo de documento: Article