Your browser doesn't support javascript.
loading
Frequency and Duration of SARS-CoV-2 Shedding in Oral Fluid Samples Assessed by a Modified Commercial Rapid Molecular Assay.
Bordi, Licia; Sberna, Giuseppe; Lalle, Eleonora; Piselli, Pierluca; Colavita, Francesca; Nicastri, Emanuele; Antinori, Andrea; Boumis, Evangelo; Petrosillo, Nicola; Marchioni, Luisa; Minnucci, Giulia; D'Agostini, Elena; Castilletti, Concetta; Locatelli, Franco; Zumla, Alimuddin; Ippolito, Giuseppe; Capobianchi, Maria Rosaria.
Afiliação
  • Bordi L; Laboratory of Virology, National Institute for Infectious Diseases "L. Spallanzani" IRCCS, 00149 Rome, Italy.
  • Sberna G; Laboratory of Virology, National Institute for Infectious Diseases "L. Spallanzani" IRCCS, 00149 Rome, Italy.
  • Lalle E; Laboratory of Virology, National Institute for Infectious Diseases "L. Spallanzani" IRCCS, 00149 Rome, Italy.
  • Piselli P; Epidemiology Department, National Institute for Infectious Diseases "L. Spallanzani" IRCCS, 00149 Rome, Italy.
  • Colavita F; Laboratory of Virology, National Institute for Infectious Diseases "L. Spallanzani" IRCCS, 00149 Rome, Italy.
  • Nicastri E; Clinical Department, National Institute for Infectious Diseases "L. Spallanzani" IRCCS, 00149 Rome, Italy.
  • Antinori A; Clinical Department, National Institute for Infectious Diseases "L. Spallanzani" IRCCS, 00149 Rome, Italy.
  • Boumis E; Clinical Department, National Institute for Infectious Diseases "L. Spallanzani" IRCCS, 00149 Rome, Italy.
  • Petrosillo N; Clinical Department, National Institute for Infectious Diseases "L. Spallanzani" IRCCS, 00149 Rome, Italy.
  • Marchioni L; Clinical Department, National Institute for Infectious Diseases "L. Spallanzani" IRCCS, 00149 Rome, Italy.
  • Minnucci G; R&D Department, DiaSorin Molecular LLC, Cypress, CA 90630, USA.
  • D'Agostini E; R&D Department, DiaSorin Molecular LLC, Cypress, CA 90630, USA.
  • Castilletti C; Laboratory of Virology, National Institute for Infectious Diseases "L. Spallanzani" IRCCS, 00149 Rome, Italy.
  • Locatelli F; Department of Pediatric Hematology and Oncology, IRCCS Ospedale Pediatrico Bambino Gesù, 00165 Rome, Italy.
  • Zumla A; Division of Infection and Immunity, University College London, London WC1E 6BT, UK.
  • Ippolito G; NIHR Biomedical Research Centre, UCL Hospitals NHS Foundation Trust, London W1T 7DN, UK.
  • Capobianchi MR; Scientific Direction, National Institute for Infectious Diseases "L. Spallanzani" IRCCS, 00149 Rome, Italy.
  • On Behalf Of Inmi ReCOVeRI Study Group; Laboratory of Virology, National Institute for Infectious Diseases "L. Spallanzani" IRCCS, 00149 Rome, Italy.
Viruses ; 12(10)2020 10 20.
Article em En | MEDLINE | ID: mdl-33092065
BACKGROUND: RT-PCR on nasopharyngeal (NPS)/oropharyngeal swabs is the gold standard for diagnosis of SARS-CoV-2 infection and viral load monitoring. Oral fluid (OF) is an alternate clinical sample, easy and safer to collect and could be useful for COVID-19 diagnosis, monitoring viral load and shedding. METHODS: Optimal assay conditions and analytical sensitivity were established for the commercial Simplexa™ COVID-19 Direct assay adapted to OF matrix. The assay was used to test 337 OF and NPS specimens collected in parallel from 164 hospitalized patients; 50 bronchoalveolar lavage (BAL) specimens from a subgroup of severe COVID-19 cases were also analysed. RESULTS: Using Simplexa™ COVID-19 Direct on OF matrix, 100% analytical detection down to 1 TCID50/mL (corresponding to 4 × 103 copies (cp)/mL) was observed. No crossreaction with other viruses transmitted through the respiratory toute was observed. Parallel testing of 337 OF and NPS samples showed highly concordant results (κ = 0.831; 95 % CI = 0.771-0.891), and high correlation of Ct values (r = 0.921; p < 0.0001). High concordance and elevated correlation was observed also between OF and BAL. Prolonged viral RNA shedding was observed up to 100 days from symptoms onset (DSO), with 32% and 29% positivity observed in OF and NPS samples, respectively, collected between 60 and 100 DSO. CONCLUSIONS: Simplexa™ COVID-19 Direct assays on OF have high sensitivity and specificity to detect SARS-CoV-2 RNA and provide an alternative to NPS for diagnosis and monitoring SARS-CoV-2 shedding.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pneumonia Viral / Eliminação de Partículas Virais / Infecções por Coronavirus / Técnicas de Laboratório Clínico / Betacoronavirus Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pneumonia Viral / Eliminação de Partículas Virais / Infecções por Coronavirus / Técnicas de Laboratório Clínico / Betacoronavirus Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article