Your browser doesn't support javascript.
loading
Fetal Brain Biometry: Is there an Agreement among Ultrasound, MRI and the Measurements at Birth?
Gafner, Michal; Fried, Shalev; Gosher, Noa; Jeddah, Danielle; Sade, Eliel Kedar; Barzilay, Eran; Mayer, Arnaldo; Katorza, Eldad.
Afiliação
  • Gafner M; Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel. Electronic address: michalgurevitch@gmail.com.
  • Fried S; Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel.
  • Gosher N; Hadassah Medical School, The Hebrew University of Jerusalem, Jerusalem, Israel.
  • Jeddah D; Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel.
  • Sade EK; Department of Obstetrics and Gynecology, Samson Assuta Ashdod Hospital, Faculty of Health Sciences, Ben-Gurion University of the Negev, Israel.
  • Barzilay E; Department of Obstetrics and Gynecology, Samson Assuta Ashdod Hospital, Faculty of Health Sciences, Ben-Gurion University of the Negev, Israel.
  • Mayer A; Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel; Department of Diagnostic Radiology, Sheba Medical Center, Ramat-Gan, Israel.
  • Katorza E; Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel; Department of Diagnostic Radiology, Sheba Medical Center, Ramat-Gan, Israel; Department of Obstetrics and Gynecology, Sheba Medical Center, Ramat-Gan, Israel.
Eur J Radiol ; 133: 109369, 2020 Dec.
Article em En | MEDLINE | ID: mdl-33126174
ABSTRACT

PURPOSE:

Measurement of the fetal brain can be achieved by different modalities, we aimed to assess the agreement between these methods and the head circumference at birth.

METHODS:

A retrospective study conducted between 2011-2018 at a tertiary referral medical center. Sonographic head circumference (HC), 2D MRI bi-parietal diameter (BPD) and occipito-frontal diameter (OFD), 3D MRI supra-tentorial volume (STV), and head circumference (HC) at birth were measured and converted into centiles according to gestational age. Spearman's rank correlation coefficient was used to assess the correlation between the modalities.

RESULTS:

A total of 88 fetuses were included. Mean gestational age at the time of fetal US and brain MRI acquisition were 34.4 ±â€¯2.8 and 34.6 ±â€¯2.6 weeks, respectively. A correlation was found between prenatal sonographic HC and the 3D MRI STV centiles (Rs = 0.859, p < 0.001), the BPD in 2D MRI (Rs = 0.813, p < 0.001), and the OFD in 2D MRI (Rs = 0.840, p < 0.001). Sonographic HC, OFD on 2D MRI, and STV on 3D MRI were all found to be correlated with the HC at birth (Rs = 0.865, p < 0.001; Rs 0.816, p < 0.001; Rs = 0.825, p < 0.001, respectively).

CONCLUSIONS:

There is a statistically significant agreement among the different prenatal clinically used modalities for measuring fetal brain and the head circumference at birth, however, this correlation is not perfect. Further study is needed to investigate the long-term prognosis of these fetuses.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Biometria Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Female / Humans / Newborn / Pregnancy Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Biometria Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Female / Humans / Newborn / Pregnancy Idioma: En Ano de publicação: 2020 Tipo de documento: Article