Your browser doesn't support javascript.
loading
Evaluation of a SARS-CoV-2 lateral flow assay using the plaque reduction neutralization test.
Xie, Xuping; Nielsen, Marisa C; Muruato, Antonio E; Fontes-Garfias, Camila R; Ren, Ping.
Afiliação
  • Xie X; Department of Biochemistry and Molecular Biology, University of Texas Medical Branch, Galveston, TX, USA.
  • Nielsen MC; Department of Pathology, University of Texas Medical Branch, Galveston, TX, USA.
  • Muruato AE; Department of Biochemistry and Molecular Biology, University of Texas Medical Branch, Galveston, TX, USA; Department of Microbiology and Immunology, University of Texas Medical Branch, Galveston, TX, USA.
  • Fontes-Garfias CR; Department of Biochemistry and Molecular Biology, University of Texas Medical Branch, Galveston, TX, USA.
  • Ren P; Department of Pathology, University of Texas Medical Branch, Galveston, TX, USA. Electronic address: piren@UTMB.edu.
Diagn Microbiol Infect Dis ; 99(2): 115248, 2021 Feb.
Article em En | MEDLINE | ID: mdl-33130510
ABSTRACT
As new tests and technologies advance our understanding and diagnostic capabilities of the severe acute respiratory syndrome coronavirus 2 and the coronavirus disease 2019, they must be appropriately validated to make sure test performance is following manufacturer claims. In this study, we evaluated the Vazyme 2019-nCoV IgG/IgM Detection Kit, which is a lateral flow assay (LFA), by the plaque reduction neutralization test (PRNT) using 100 patient plasma/serum samples. As compared to the PRNT results, the Vazyme LFA had 95.9% sensitivity and 96.1% specificity. Along with the increased need for rapid, effective, and affordable point of care tests to help provide meaningful epidemiological data, we demonstrated that the Vazyme LFA performed well on IgG detection but cannot be judged on the performance of IgM detection using PRNT alone. However, our observation of the low IgM-positive rate supported the poor performance of IgM detection of this LFA which led to the disapproval of its Emergency Use Authorization recently.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ensaio de Placa Viral / Testes de Neutralização / SARS-CoV-2 / COVID-19 / Anticorpos Antivirais Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ensaio de Placa Viral / Testes de Neutralização / SARS-CoV-2 / COVID-19 / Anticorpos Antivirais Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article