Your browser doesn't support javascript.
loading
Brain Atrophy Following Deep Brain Stimulation: Management of a Moving Target.
Chiu, Shannon Y; Deeb, Wissam; Zeilman, Pamela; Ramirez-Zamora, Adolfo; Patterson, Addie; Patel, Bhavana; Foote, Kelly D; Okun, Michael S; Patel, Amar; Almeida, Leonardo.
Afiliação
  • Chiu SY; Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida, Gainesville, FL, US.
  • Deeb W; Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida, Gainesville, FL, US.
  • Zeilman P; Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida, Gainesville, FL, US.
  • Ramirez-Zamora A; Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida, Gainesville, FL, US.
  • Patterson A; Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida, Gainesville, FL, US.
  • Patel B; Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida, Gainesville, FL, US.
  • Foote KD; Department of Neurosurgery, Norman Fixel Institute for Neurological Diseases, University of Florida, Gainesville, FL, US.
  • Okun MS; Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida, Gainesville, FL, US.
  • Patel A; Department of Neurology, Yale school of Medicine, Yale University, New Haven, CT, US.
  • Almeida L; Department of Neurology, Norman Fixel Institute for Neurological Diseases, University of Florida, Gainesville, FL, US.
Article em En | MEDLINE | ID: mdl-33133768
ABSTRACT
Clinical vignette A 51-year-old man with essential tremor (ET) had bilateral ventralis intermedius nucleus deep brain stimulation (VIM-DBS) placed to address refractory tremor. Despite well-placed DBS leads and adequate tremor response, he subsequently experienced worsening. Re-programming of the device and reconfirming the electrical thresholds for benefits and side effects were both performed. Six years following DBS implantation, repeat imaging revealed brain atrophy and a measured lead position change with a coincident change in clinical response. Clinical dilemma What do we know about brain atrophy affecting lead placement and long-term DBS effectiveness? What are the potential strategies to combat narrowed therapeutic thresholds and to maximize DBS therapeutic benefit? Clinical solution Decreasing the electrical field of stimulation and programming in a bipolar configuration are strategies to provide symptomatic tremor control and to minimize stimulation-induced side effects. Gaps in knowledge Currently, effects of brain atrophy, and factors underpinning emergence of side effects and/or loss of benefit in chronic VIM-DBS remain largely unexplored.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Falha de Prótese / Núcleos Ventrais do Tálamo / Tremor Essencial / Estimulação Encefálica Profunda / Neuroestimuladores Implantáveis Limite: Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Falha de Prótese / Núcleos Ventrais do Tálamo / Tremor Essencial / Estimulação Encefálica Profunda / Neuroestimuladores Implantáveis Limite: Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article