Your browser doesn't support javascript.
loading
Assessment of bronchial obstruction and its reversibility by shape indexes of the flow-volume loop in asthmatic children.
Berrier, Amaury; Tiotiu, Angelica; Bonabel, Claude; Richard, David; Nguyen-Thi, Phi Linh; Demoulin-Alexikova, Silvia; Schweitzer, Cyril; Ioan, Iulia.
Afiliação
  • Berrier A; Department of Pulmonology, University Children's Hospital of Nancy, Nancy, France.
  • Tiotiu A; Department of Pulmonology, University Children's Hospital of Nancy, Nancy, France.
  • Bonabel C; DevAH, Université de Lorraine, Nancy, France.
  • Richard D; DevAH, Université de Lorraine, Nancy, France.
  • Nguyen-Thi PL; Department of Pediatric Respiratory Function Testing, University Children's Hospital of Nancy, Nancy, France.
  • Demoulin-Alexikova S; Department of Pediatric Respiratory Function Testing, University Children's Hospital of Nancy, Nancy, France.
  • Schweitzer C; Department of Methodology, Promotion, Investigation-MPI, University Children's Hospital of Nancy, Nancy, France.
  • Ioan I; DevAH, Université de Lorraine, Nancy, France.
Pediatr Pulmonol ; 56(1): 226-233, 2021 01.
Article em En | MEDLINE | ID: mdl-33169929
Asthma assessment by spirometry is challenging in children as forced expiratory volume in 1 s (FEV1) is frequently normal at baseline. Bronchodilator (BD) reversibility testing may reinforce asthma diagnosis but FEV1 sensitivity in children is controversial. Ventilation inhomogeneity, an early sign of airway obstruction, is described by the upward concavity of the descending limb of the forced expiratory flow-volume loop (FVL), not detected by FEV1. The aim was to test the sensitivity and specificity of FVL shape indexes as ß-angle and forced expiratory flow at 50% of the forced vital capacity (FEF50)/peak expiratory flow (PEF) ratio, to identify asthmatics from healthy children in comparison to "usual" spirometric parameters. Seventy-two school-aged asthmatic children and 29 controls were prospectively included. Children performed forced spirometry at baseline and after BD inhalation. Parameters were expressed at baseline as z-scores and BD reversibility as percentage of change reported to baseline value (Δ%). Receiver operating characteristic curves were generated and sensitivity and specificity at respective thresholds reported. Asthmatics presented significantly smaller zß-angle, zFEF50/PEF and zFEV1 (p ≤ .04) and higher BD reversibility, significant for Δ%FEF50/PEF (p = .02) with no difference for Δ%FEV1. zß-angle and zFEF50/PEF exhibited better sensitivity (0.58, respectively 0.60) than zFEV1 (0.50), and similar specificity (0.72). Δ%ß-angle showed higher sensitivity compared to Δ%FEV1 (0.72 vs. 0.42), but low specificity (0.52 vs. 0.86). Quantitative and qualitative assessment of FVL by adding shape indexes to spirometry interpretation may improve the ability to detect an airway obstruction, FEV1 reflecting more proximal while shape indexes peripheral bronchial obstruction.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Asma / Broncodilatadores / Volume Expiratório Forçado Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Qualitative_research Limite: Child / Female / Humans / Male Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Asma / Broncodilatadores / Volume Expiratório Forçado Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Qualitative_research Limite: Child / Female / Humans / Male Idioma: En Ano de publicação: 2021 Tipo de documento: Article