Your browser doesn't support javascript.
loading
Molecular characterization of solitary pulmonary nodules in dual-energy CT nonlinear image fusion technology.
Li, Qian; Tan, Huan; Lv, Furong.
Afiliação
  • Li Q; Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Tan H; Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Lv F; Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
J Recept Signal Transduct Res ; 42(1): 95-99, 2022 Feb.
Article em En | MEDLINE | ID: mdl-33256505
OBJECTIVE: To investigate the feasibility and to optimize the parameters of nonlinear blending technique in dual-energy CT on solitary pulmonary nodules (SPN). METHODS: The simulated enhanced SPN were used the mixture of nonionic iodinated contrast agent (Iopromide 370mgI/100 ml) and normal saline and then randomly placed inside an anthropomorphic chest phantom. The phantom was examined on SOMATOM definition flash with dual mode (80/140 kV) and single energy mode (120 kV) (the same CTDIvol). Nonlinear blending images and linear blending images with a weighting factor of 0.3 were generated and the image qualities were analyzed. RESULTS: For different simulated density SPN, when 0 HU was chosen as the Blending Center (BC) and 0 to 30 HU were chosen as the Blending width (BW), the nonlinear blending images yielded a higher contrast-to-noise (CNR). There were significant differences in the image noise and signal-to-noise (SNR) of different simulated density SPN at non-linear blending images, linear blending images and 120 kV images (p < .05); But the differences of CNR between the three groups were not statistically significant (p > .05). The SNR of different simulated density SPN at non-linear blending images was significantly increased compared with it at linear blending images and 120 kV images (p < .05); And the image noise at non-linear blending was lower than it at linear blending images (p < .05). CONCLUSION: Nonlinear blending technique in dual-energy CT can increase the SNR of enhanced SPN, and it is helpful in diagnosis of SPN.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Radiográfica Assistida por Computador / Nódulo Pulmonar Solitário Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Radiográfica Assistida por Computador / Nódulo Pulmonar Solitário Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article