Your browser doesn't support javascript.
loading
Influence of surrounding temperature and angle of file access on cyclic fatigue resistance of two single file nickel-titanium instruments.
La Rosa, Giusy Rita Maria; Palermo, Carlotta; Ferlito, Sebastiano; Isola, Gaetano; Indelicato, Francesco; Pedullà, Eugenio.
Afiliação
  • La Rosa GRM; Department of General Surgery and Medical - Surgical Specialties, University of Catania, Catania, Italy.
  • Palermo C; Department of General Surgery and Medical - Surgical Specialties, University of Catania, Catania, Italy.
  • Ferlito S; Department of General Surgery and Medical - Surgical Specialties, University of Catania, Catania, Italy.
  • Isola G; Department of General Surgery and Medical - Surgical Specialties, University of Catania, Catania, Italy.
  • Indelicato F; Department of General Surgery and Medical - Surgical Specialties, University of Catania, Catania, Italy.
  • Pedullà E; Department of General Surgery and Medical - Surgical Specialties, University of Catania, Catania, Italy.
Aust Endod J ; 47(2): 260-264, 2021 Aug.
Article em En | MEDLINE | ID: mdl-33277785
ABSTRACT
The purpose of this study was to evaluate the influence of surrounding temperature and angle of file access on cyclic fatigue resistance of F6 SkyTaper (F6ST) and One Curve (OC). 120 new files #25.06 were tested at two insertion angles (0° and 20°) at room (20°C ± 1°C) and body (35°C ± 1°C) temperatures in a 16-mm stainless steel artificial canal (60° curvature and 5-mm radius), using a customised device. Cyclic fatigue resistance was expressed as time to fracture (TtF) in seconds. Data were analysed statistically (P < 0.05). All instruments exhibited lower TtF at 35°C (P < 0.05). An access of 20° did not significantly influence the TtF of tested instruments, independently from the temperature. OC exhibited higher TtF of F6ST at 20°C with a 20° inclination (P < 0.05). Under the present conditions, F6ST and OC showed a significant reduction of cyclic fatigue resistance at body temperature. A file inclined insertion did not affect the cyclic fatigue resistance of tested instruments at both temperatures.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Instrumentos Odontológicos / Níquel Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Instrumentos Odontológicos / Níquel Idioma: En Ano de publicação: 2021 Tipo de documento: Article