Simultaneous diffuse optical and bioluminescence tomography to account for signal attenuation to improve source localization.
Bentley, Alexander; Rowe, Jonathan E; Dehghani, Hamid.
Afiliação
  • Bentley A; School of Computer Science, College of Engineering and Physical Sciences, University of Birmingham, UK.
  • Rowe JE; Physical Sciences for Health Doctoral Training Centre, College of Engineering and Physical Sciences, University of Birmingham, UK.
  • Dehghani H; School of Computer Science, College of Engineering and Physical Sciences, University of Birmingham, UK.
Biomed Opt Express ; 11(11): 6428-6444, 2020 Nov 01.
Article em En | MEDLINE | ID: mdl-33282499
ABSTRACT
Photonics based pre-clinical imaging is an extensively used technique to allow for the study of biologically relevant activity typically within a small-mouse model. Namely, bioluminescent tomography (BLT) attempts to tomographically reconstruct the 3-dimensional spatial light distribution of luminophores within a small animal given surface light measurements and known underlying optical parameters. Often it is the case where these optical parameters are unknown leading to the use of a 'best' guess approach or to direct measurements using either a multi-modal or dedicated system. Using these conventional approaches can lead to both inaccurate results and extending periods of imaging time. This work introduces the development of an algorithm that is used to accurately localize the spatial light distribution from a bioluminescence source within a subject by simultaneously reconstructing both the underlying optical properties and source spatial distribution and intensity from the same set of surface measurements. Through its application in 2- and 3-dimensional, homogeneous and heterogenous numerical models, it is demonstrated that the proposed algorithm is capable of replicating results as compared to 'gold' standard where the absolute optical properties are known. Additionally, the algorithm has been applied to experimental data using a tissue mimicking block phantom, recovering a spatial light distribution that has a localization error of ∼1.53 mm, which is better than previously published results without the need of assumptions regarding the underlying optical properties or source distribution.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article