Your browser doesn't support javascript.
loading
Functional and radiological outcomes after treatment with custom-made acetabular components in patients with Paprosky type 3 acetabular defects: short-term results.
Gruber, Michael S; Jesenko, Michael; Burghuber, Julia; Hochreiter, Josef; Ritschl, Peter; Ortmaier, Reinhold.
Afiliação
  • Gruber MS; Unfallkrankenhaus Linz, Linz, 4020, Upper Austria, Austria.
  • Jesenko M; Orthopedic Hospital Gersthof, Vienna, 1180, Austria.
  • Burghuber J; Unfallkrankenhaus Linz, Linz, 4020, Upper Austria, Austria.
  • Hochreiter J; Department of Orthopedic Surgery, Ordensklinikum Barmherzige Schwestern Linz, Vinzenzgruppe Center of Orthopedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Linz, 4020, Austria.
  • Ritschl P; Orthopedic Hospital Gersthof, Vienna, 1180, Austria.
  • Ortmaier R; Department of Orthopedic Surgery, Ordensklinikum Barmherzige Schwestern Linz, Vinzenzgruppe Center of Orthopedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Linz, 4020, Austria. r.ortmaier@gmail.com.
BMC Musculoskelet Disord ; 21(1): 835, 2020 Dec 10.
Article em En | MEDLINE | ID: mdl-33302907
ABSTRACT

BACKGROUND:

Severe acetabular defects require special treatment with either impaction bone grafting, metal augmented cups or cup-cage constructs. Even these options are often not adequate, especially in hips with Paprosky type 3 defects with loss of anterior and posterior columns. This study investigates the clinical and radiological outcomes of custom-made acetabular components (© Materialise NV, Leuven, Belgium) for Paprosky type 3 defects.

METHODS:

Sixteen patients were eligible for this trial, nine of whom agreed to be included. All of them completed one year of follow-up. The Harris hip score and the Oxford hip score were used to compare pre- and postoperative functional outcomes. Radiological follow-up comprised anteversion and inclination of the implanted cup and offset measurements in both hips (femoral, medial, ischial offset and center of rotation). Statistical analyses were performed with IBM SPSS Statistics.

RESULTS:

The mean follow-up time of the nine patients was 12.2 months (range 10-18). The Oxford hip score and Harris hip score improved from 19.8 and 50.1 to 29.4 and 68.8, respectively (p = 0.009 and 0.01). There were complications in three cases (33.3%), which led to one re-revision (11.1%). Radiologic follow-up showed restoration of the height of the center of rotation and of the global offset. Significant difference was detected in the femoral offset.

CONCLUSIONS:

The functional and radiological outcomes are promising. However, long-term outcomes still need to be examined. LEVEL OF EVIDENCE Therapeutic Level IV.