Transabdominal and transperineal ultrasound vs routine care before instrumental vaginal delivery - A randomized controlled trial.
Acta Obstet Gynecol Scand
; 100(6): 1075-1081, 2021 06.
Article
em En
| MEDLINE
| ID: mdl-33319355
INTRODUCTION: The role of intrapartum ultrasound as an ancillary method to instrumental vaginal delivery is yet to be determined. This study aimed to compare the use of transabdominal and transperineal ultrasound with routine clinical care before performing an instrumental vaginal delivery, regarding the incidence of adverse maternal and neonatal outcomes. MATERIAL AND METHODS: A randomized controlled trial was conducted between October 2016 and March 2019 in two tertiary care maternity hospitals in Lisbon, Portugal. Women at term, with full cervical dilatation, singleton fetuses in cephalic presentation, and with an established indication for instrumental vaginal delivery, were approached for enrollment. After informed consent was obtained, randomization into one of two groups was carried out. In the experimental arm, women underwent transabdominal ultrasound for determination of the fetal head position and transperineal ultrasound for evaluation of the angle of progression, before instrumental vaginal delivery. In the control arm, no ultrasound was carried out before instrumental vaginal delivery. Primary outcomes were composite measures of maternal and neonatal morbidity. Composite maternal morbidity consisted of severe postpartum hemorrhage, perineal trauma, and prolonged hospital stay. Composite neonatal morbidity consisted of low 5-minute Apgar score, umbilical artery metabolic acidosis, birth trauma, and neonatal intensive care unit admission. RESULTS: A total of 222 women were enrolled (113 in the experimental arm and 109 in the control arm). No significant differences between the two arms were found in composite measures of maternal (23.9% in the experimental group vs 22.9% in the control group, odds ratio 1.055, 95% CI 0.567-1.964) or neonatal morbidity (9.7% in the experimental group vs 6.4% in the control group, odds ratio 1.571, 95% CI 0.586-4.215), nor in any of the individual outcomes. CONCLUSIONS: In this small randomized controlled trial that was stopped for futility before reaching the required sample size, transabdominal and transperineal ultrasound performed just before instrumental vaginal delivery did not reduce the incidence of adverse maternal and neonatal outcomes, when compared with routine clinical care.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Vácuo-Extração
/
Segunda Fase do Trabalho de Parto
/
Resultado da Gravidez
/
Ultrassonografia Pré-Natal
/
Apresentação no Trabalho de Parto
Tipo de estudo:
Clinical_trials
/
Diagnostic_studies
Limite:
Adult
/
Female
/
Humans
/
Newborn
/
Pregnancy
Idioma:
En
Ano de publicação:
2021
Tipo de documento:
Article