Your browser doesn't support javascript.
loading
Bulk Wave Velocities in Cortical Bone Reflect Porosity and Compression Strength.
Peralta, Laura; Maeztu Redin, Juan Deyo; Fan, Fan; Cai, Xiran; Laugier, Pascal; Schneider, Johannes; Raum, Kay; Grimal, Quentin.
Afiliação
  • Peralta L; Sorbonne Universite, INSERM, CNRS, Laboratoire d'lmagerie Biomedicale, LIB, F-75006 Paris, France; Department of Biomedical Engineering, School of Biomedical Engineering & Imaging Sciences, Kings College London, London, United Kingdom. Electronic address: laura.peralta_pereira@kcl.ac.uk.
  • Maeztu Redin JD; Sorbonne Universite, INSERM, CNRS, Laboratoire d'lmagerie Biomedicale, LIB, F-75006 Paris, France.
  • Fan F; Sorbonne Universite, INSERM, CNRS, Laboratoire d'lmagerie Biomedicale, LIB, F-75006 Paris, France; Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.
  • Cai X; Sorbonne Universite, INSERM, CNRS, Laboratoire d'lmagerie Biomedicale, LIB, F-75006 Paris, France.
  • Laugier P; Sorbonne Universite, INSERM, CNRS, Laboratoire d'lmagerie Biomedicale, LIB, F-75006 Paris, France.
  • Schneider J; Berlin-Brandenburg School for Regenerative Therapies, Charit-Universittsmedizin Berlin, Berlin, Germany.
  • Raum K; Berlin-Brandenburg School for Regenerative Therapies, Charit-Universittsmedizin Berlin, Berlin, Germany.
  • Grimal Q; Sorbonne Universite, INSERM, CNRS, Laboratoire d'lmagerie Biomedicale, LIB, F-75006 Paris, France.
Ultrasound Med Biol ; 47(3): 799-808, 2021 03.
Article em En | MEDLINE | ID: mdl-33341302
ABSTRACT
The goal of this study was to evaluate whether ultrasonic velocities in cortical bone can be considered as a proxy for mechanical quality of cortical bone tissue reflected by porosity and compression strength. Micro-computed tomography, compression mechanical testing and resonant ultrasound spectroscopy were used to assess, respectively, porosity, strength and velocity of bulk waves of both shear and longitudinal polarisations propagating along and perpendicular to osteons, in 92 cortical bone specimens from tibia and femur of elderly human donors. All velocities were significantly associated with strength (r = 0.65-0.83) and porosity (r = -0.64 to -0.77). Roughly, according to linear regression models, a decrease in velocity of 100 m/s corresponded to a loss of 20 MPa in strength (which is approximately 10% of the largest strength value) and to an increase in porosity of 5%. These results provide a rationale for the in vivo measurement of one or several velocities for the diagnosis of bone fragility.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ondas Ultrassônicas / Osso Cortical Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ondas Ultrassônicas / Osso Cortical Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Ano de publicação: 2021 Tipo de documento: Article