Your browser doesn't support javascript.
loading
Effect of interfacial structure based on grafting density of poly(2-methoxyethyl acrylate) on blood compatibility.
Ueda, Tomoya; Murakami, Daiki; Tanaka, Masaru.
Afiliação
  • Ueda T; Graduate School of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka, 819-0395, Japan.
  • Murakami D; Graduate School of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka, 819-0395, Japan; Institute for Materials Chemistry and Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka, 819-0395, Japan.
  • Tanaka M; Graduate School of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka, 819-0395, Japan; Institute for Materials Chemistry and Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka, 819-0395, Japan. Electronic address: masaru_tanaka@ms.ifoc.kyushu-u.ac.jp.
Colloids Surf B Biointerfaces ; 199: 111517, 2021 Mar.
Article em En | MEDLINE | ID: mdl-33352490
ABSTRACT
An excellent blood-compatible polymer, poly(2-methoxyethyl acrylate) (PMEA), exhibits nanometer-scale phase-separated structures at the interface with water or phosphate-buffered saline (PBS), and fibrinogen adsorption is suppressed, especially on the water-rich region. To understand the correlation between the interfacial structure based on the grafting density of PMEA and blood compatibility, grafted PMEA (gPMEA) surfaces with controlled density were prepared by immobilizing thiol-terminated PMEA on a gold substrate. The amount of adsorbed fibrinogen and the number of adhered platelets on gPMEAs decreased first with the increasing grafting density (σ), but increased after showed minimum at σ of approximately 0.11 chains/nm2. The interfacial structures of the gPMEA/PBS interface changed with grafting density, and the maximum area of water-rich region was obtained at σ = 0.11. The water contact angle at σ = 0.11 is smaller than that at the other grafting density. These results revealed that hydration to the polymer is very effective to suppress the platelet adhesion and water-rich region shows excellent blood compatibility on gPMEA surfaces. This work clearly indicated that the density of PMEA affects the interfacial structure and plays an important role in the blood compatibility of the material.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Materiais Biocompatíveis Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Materiais Biocompatíveis Idioma: En Ano de publicação: 2021 Tipo de documento: Article