Your browser doesn't support javascript.
loading
Diagnostic accuracy of postmortem computed tomography for bleeding source determination in cases with hemoperitoneum.
Chatzaraki, Vasiliki; Thali, Michael J; Ampanozi, Garyfalia.
Afiliação
  • Chatzaraki V; Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, University of Zurich, Winterthurerstrasse 190/52, CH-8057, Zurich, Switzerland. chatzaraki@outlook.com.gr.
  • Thali MJ; Department of Radiology, Kantonsspital Baden AG, Im Ergel 1, CH-5404, Baden, Switzerland. chatzaraki@outlook.com.gr.
  • Ampanozi G; Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, University of Zurich, Winterthurerstrasse 190/52, CH-8057, Zurich, Switzerland.
Int J Legal Med ; 135(2): 593-603, 2021 Mar.
Article em En | MEDLINE | ID: mdl-33410928
ABSTRACT

AIM:

The aim of this retrospective study was to determine the accuracy of postmortem computed tomography and different radiological signs for the determination of the bleeding source in cases with hemoperitoneum confirmed at autopsy.

METHODS:

Postmortem computed tomography data of consecutive cases with hemoperitoneum confirmed at autopsy were reviewed by two raters, blinded to the autopsy findings. The determination of possible bleeding sources was based on the presence of the sentinel clot sign, blood or sedimented blood surrounding an organ, intraparenchymal abnormal gas distribution, and parenchymal disruption. The bleeding source and the cause of hemoperitoneum (traumatic, surgical, natural, or resuscitation) as reported in the autopsy report were noted. The survival intervals of the deceased were calculated when information about the time of an incident related to death was available in the autopsy reports.

RESULTS:

Eighty-five cases were included in the study. Postmortem computed tomography showed 79% sensitivity and 92.1% specificity for the detection of the bleeding source. The sentinel clot sign was associated with surgical or natural causes of hemoperitoneum and longer survival intervals. Sedimented blood around the bleeding source was associated with resuscitation. Abnormal gas distribution within organs and combination of multiple radiological signs provided higher sensitivity.

CONCLUSION:

Postmortem computed tomography provides moderate sensitivity and high specificity for determining the bleeding source in cases with hemoperitoneum. Different PMCT signs are associated with different causes of hemoperitoneum and survival intervals.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Patologia Legal / Hemoperitônio Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Patologia Legal / Hemoperitônio Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article