Your browser doesn't support javascript.
loading
Coliphages as Indicators for the Microbial Quality of Treated Wastewater Effluents.
Nasser, Abidelfatah; Sasi, Sivan; Nitzan, Yeshayahu.
Afiliação
  • Nasser A; Water Quality Research Laboratory, National Public Health Laboratory, Ministry of Health, Tel Aviv, Israel. abid.nasser@phlta.health.gov.il.
  • Sasi S; Water Quality Research Laboratory, National Public Health Laboratory, Ministry of Health, Tel Aviv, Israel.
  • Nitzan Y; Faculty of Life Sciences, Bar-Ilan University, Ramat Gan, Israel.
Food Environ Virol ; 13(2): 170-178, 2021 06.
Article em En | MEDLINE | ID: mdl-33428162
ABSTRACT
Wastewater effluents are a reliable water source for non-potable water reuse including unrestricted crop irrigation in arid regions suffering from water scarcity. This study was performed to develop and optimize a procedure to concentrate coliphages from 100 L of treated effluent. Moreover, the reduction of coliphages by filtration and disinfection by either chlorine or UV was compared with that of fecal coliform (FC). The adsorption efficiency of MS2 and Qß coliphages by the NanoCeram filter was similar and reached 99.8%. Elution efficiency of MS2 coliphage from the NanoCeram filters by a solution of 1% NaPP and 0.05 M glycine, pH 9.5, was 74  ±  9.5%. The highest reconcentration efficiency of MS2 and Qß coliphages was obtained with polyethylene glycol (PEG) precipitation and reached 76  ±  28% and 90  ±  11%, respectively. In comparison, the reconcentration efficiency of organic flocculation was 0% and 1.3% for Qß and MS2 coliphages, respectively. The overall recovery efficiency of MS2 coliphages from 100 L tertiary effluent was 57  ±  1.5%. Poor reduction was observed for coliphages compared to FC by filtration and chlorine disinfection although; the reduction of FC, as measured by cultivation, was satisfactory and within the guidelines for unrestricted irrigation. High correlation between the reduction of FC and coliphages was recorded for tertiary effluent disinfected by UV irradiation. Monitoring the microbial quality of tertiary effluent using qPCR for the enumeration of FC was found unsuitable, because DNA levels were unaffected by the treatment processes. The results of this study demonstrated that monitoring the microbial quality of tertiary effluent by FC may not reflect the health risks encountered by the application of these effluents and the addition of coliphages to the monitoring programs may allow for accurate assessment of the health risks introduced by the application of tertiary effluent.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cloro / Desinfecção / Colífagos / Purificação da Água / Desinfetantes / Águas Residuárias Tipo de estudo: Guideline Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cloro / Desinfecção / Colífagos / Purificação da Água / Desinfetantes / Águas Residuárias Tipo de estudo: Guideline Idioma: En Ano de publicação: 2021 Tipo de documento: Article