Your browser doesn't support javascript.
loading
Validation of a HPLC method for quantification of midazolam in rat plasma: Application during a Maytenus ilicifolia-drug interaction study.
do Nascimento, Sara Batista; de Lima Nascimento, Mariana; Duarte-Almeida, Joaquim Maurício; de Oliveira, Flávio Martins; do Carmo Vieira, Maria; Siqueira, João Máximo; de Andrade, Frank Pereira; da Costa César, Isabela; de Castro, Whocely Victor.
Afiliação
  • do Nascimento SB; Federal University of São João del-Rei, Divinópolis, Minas Gerais, Brazil.
  • de Lima Nascimento M; Federal University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil.
  • Duarte-Almeida JM; Federal University of São João del-Rei, Divinópolis, Minas Gerais, Brazil.
  • de Oliveira FM; Federal University of São João del-Rei, Divinópolis, Minas Gerais, Brazil.
  • do Carmo Vieira M; Federal University of São João del-Rei, Divinópolis, Minas Gerais, Brazil.
  • Siqueira JM; Federal University of Grande Dourados R. João Rosa Góes, Mato Grosso, do Sul, Brazil.
  • de Andrade FP; Federal University of São João del-Rei, Divinópolis, Minas Gerais, Brazil.
  • da Costa César I; Federal University of São João del-Rei, Divinópolis, Minas Gerais, Brazil.
  • de Castro WV; Federal University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil.
Biomed Chromatogr ; 35(3): e4999, 2021 Mar.
Article em En | MEDLINE | ID: mdl-33460183
ABSTRACT
Midazolam (MDZ) is routinely employed as a marker compound of cytochrome P450 3A (CYP3A) activity. Despite the many HPLC-UV methods described to quantify MDZ in plasma, all of them use acetonitrile (ACN) or a mixture of methanol-isopropanol as organic solvent of the mobile phase. Since the ACN shortage in 2008, efforts have been made to replace this solvent during HPLC analysis. A simple, sensitive, accurate and repeatable HPLC-UV method (220 nm) was developed and validated to quantify MDZ in rat plasma using methanol instead. The method was applied during a herb-drug interaction study involving Maytenus ilicifolia, a Brazilian folk medicine used to treat gastric disorders. Plasma samples were alkalinized and MDZ plus alprazolam (internal standard) were extracted with diethyl ether. After solvent removal, the residue was reconstituted with methanol-water (11). The analyte was eluted throughout a C18 column using sodium acetate buffer (10 mm, pH 7.4)-methanol (4060, v/v). The precision at the lower limit of quantification never exceeded 19.40%, and 13.86% at the higher levels of quality control standards, whereas the accuracy ranged from -19.81 to 14.33%. The analytical curve was linear from 50 to 2,000 ng/ml. The activity of the hepatic CYP3A enzymes was not affected by the extract.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Midazolam / Cromatografia Líquida de Alta Pressão / Maytenus / Interações Ervas-Drogas Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Midazolam / Cromatografia Líquida de Alta Pressão / Maytenus / Interações Ervas-Drogas Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2021 Tipo de documento: Article