Ultralow temperature cryoablation: Safety and efficacy of preclinical atrial and ventricular lesions.
Bourier, Felix; Takigawa, Masateru; Lam, Anna; Vlachos, Konstantinos; Ramirez, F Daniel; Martin, Claire A; Frontera, Antonio; Kitamura, Takeshi; Duchateau, Josselin; Pambrun, Thomas; Derval, Nicolas; Denis, Arnaud; Cox, Jerry; Cabrita, David; Babkin, Alexander; Constantin, Marion; Jais, Pierre; Sacher, Frédéric; Dubois, Rémi; Bernus, Oliver; Haissaguerre, Michel; Hocini, Mélèze.
Afiliação
  • Bourier F; IHU LIRYC ANR-10-IAHU-04, Electrophysiology and Heart Modeling Institute, University of Bordeaux, Bordeaux-Pessac, France.
  • Takigawa M; Hôpital Cardiologique du Haut Lévêque, CHU Bordeaux, Bordeaux-Pessac, France.
  • Lam A; IHU LIRYC ANR-10-IAHU-04, Electrophysiology and Heart Modeling Institute, University of Bordeaux, Bordeaux-Pessac, France.
  • Vlachos K; Hôpital Cardiologique du Haut Lévêque, CHU Bordeaux, Bordeaux-Pessac, France.
  • Ramirez FD; IHU LIRYC ANR-10-IAHU-04, Electrophysiology and Heart Modeling Institute, University of Bordeaux, Bordeaux-Pessac, France.
  • Martin CA; Hôpital Cardiologique du Haut Lévêque, CHU Bordeaux, Bordeaux-Pessac, France.
  • Frontera A; IHU LIRYC ANR-10-IAHU-04, Electrophysiology and Heart Modeling Institute, University of Bordeaux, Bordeaux-Pessac, France.
  • Kitamura T; Hôpital Cardiologique du Haut Lévêque, CHU Bordeaux, Bordeaux-Pessac, France.
  • Duchateau J; IHU LIRYC ANR-10-IAHU-04, Electrophysiology and Heart Modeling Institute, University of Bordeaux, Bordeaux-Pessac, France.
  • Pambrun T; Hôpital Cardiologique du Haut Lévêque, CHU Bordeaux, Bordeaux-Pessac, France.
  • Derval N; IHU LIRYC ANR-10-IAHU-04, Electrophysiology and Heart Modeling Institute, University of Bordeaux, Bordeaux-Pessac, France.
  • Denis A; Hôpital Cardiologique du Haut Lévêque, CHU Bordeaux, Bordeaux-Pessac, France.
  • Cox J; IHU LIRYC ANR-10-IAHU-04, Electrophysiology and Heart Modeling Institute, University of Bordeaux, Bordeaux-Pessac, France.
  • Cabrita D; Hôpital Cardiologique du Haut Lévêque, CHU Bordeaux, Bordeaux-Pessac, France.
  • Babkin A; IHU LIRYC ANR-10-IAHU-04, Electrophysiology and Heart Modeling Institute, University of Bordeaux, Bordeaux-Pessac, France.
  • Constantin M; Hôpital Cardiologique du Haut Lévêque, CHU Bordeaux, Bordeaux-Pessac, France.
  • Jais P; IHU LIRYC ANR-10-IAHU-04, Electrophysiology and Heart Modeling Institute, University of Bordeaux, Bordeaux-Pessac, France.
  • Sacher F; Hôpital Cardiologique du Haut Lévêque, CHU Bordeaux, Bordeaux-Pessac, France.
  • Dubois R; IHU LIRYC ANR-10-IAHU-04, Electrophysiology and Heart Modeling Institute, University of Bordeaux, Bordeaux-Pessac, France.
  • Bernus O; Hôpital Cardiologique du Haut Lévêque, CHU Bordeaux, Bordeaux-Pessac, France.
  • Haissaguerre M; IHU LIRYC ANR-10-IAHU-04, Electrophysiology and Heart Modeling Institute, University of Bordeaux, Bordeaux-Pessac, France.
  • Hocini M; Hôpital Cardiologique du Haut Lévêque, CHU Bordeaux, Bordeaux-Pessac, France.
J Cardiovasc Electrophysiol ; 32(3): 570-577, 2021 03.
Article em En | MEDLINE | ID: mdl-33476463
ABSTRACT

BACKGROUND:

Ultralow temperature cyroablation (ULTC) is designed to create focal, linear, and circumferential lesions. The aim of this study was to assess the safety, efficacy, and durability of atrial and ventricular ULTC lesions in preclinical large animal models. METHODS AND

RESULTS:

The ULTC system uses nitrogen near its liquid-vapor critical point to cool 11-cm ablation catheters. The catheter can be shaped to specific anatomies using pre-shaped stylets. ULTC was used in 11 swine and four sheep to create atrial (pulmonary vein isolation and linear ablation) and ventricular lesions. Acute and 90-day success were evaluated by intracardiac mapping and histologic examination. Cryoadherence was observed during all ULTC applications, ensuring catheter stability at target locations. Local electrograms were completely eliminated immediately after the first single-shot ULTC application in 49 of 53 (92.5%) atrial and in 31 of 32 (96.9%) ventricular applications. Lesion depth as measured on histology preparations was 1.96 ± 0.8 mm in atrial and 5.61 ± 2.2 mm in ventricular lesions. In all animals, voltage maps and histology demonstrated transmural and durable lesions without gaps, surrounded by intact collagen fibers without injury to surrounding tissues. Transient coronary spasm could be provoked with endocardial ULTC in the left ventricle in close proximity to a coronary artery.

CONCLUSIONS:

ULTC created effective and efficient atrial and ventricular lesions in vivo without procedural complications in two large animal models. ULTC lesions were transmural, contiguous, and durable over 3 months.