Your browser doesn't support javascript.
loading
Performance Characteristics of BinaxNOW COVID-19 Antigen Card for Screening Asymptomatic Individuals in a University Setting.
Okoye, Nkemakonam C; Barker, Adam P; Curtis, Kenneth; Orlandi, Richard R; Snavely, Emily A; Wright, Cameron; Hanson, Kimberly E; Pearson, Lauren N.
Afiliação
  • Okoye NC; Department of Pathology, University of Utah School of Medicine, Salt Lake City, Utah, USA.
  • Barker AP; Department of Pathology, Section of Clinical Microbiology, University of Utah School of Medicine, Salt Lake City, Utah, USA.
  • Curtis K; ARUP Laboratories Institute for Clinical and Experimental Pathology, Salt Lake City, Utah, USA.
  • Orlandi RR; ARUP Laboratories, Salt Lake City, Utah, USA.
  • Snavely EA; Department of Surgery, Division of Otolaryngology-Head and Neck Surgery, University of Utah School of Medicine, Salt Lake City, Utah, USA.
  • Wright C; Department of Pathology, University of Utah School of Medicine, Salt Lake City, Utah, USA.
  • Hanson KE; University of Utah Medical Group, Salt Lake City, Utah, USA.
  • Pearson LN; Department of Pathology, Section of Clinical Microbiology, University of Utah School of Medicine, Salt Lake City, Utah, USA.
J Clin Microbiol ; 59(4)2021 03 19.
Article em En | MEDLINE | ID: mdl-33509809
ABSTRACT
We compared the performance of the Abbott BinaxNOW COVID-19 antigen card to that of a standard reverse transcription-PCR (RT-PCR) assay (Thermo Fisher TaqPath COVID-19 Combo kit) for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in 2,645 asymptomatic students presenting for screening at the University of Utah. SARS-CoV-2 RNA was detected in 1.7% of the study participants by RT-PCR. BinaxNOW identified 24 infections but missed 21 infections that were detected by RT-PCR. The analytical sensitivity (positive agreement) and analytical specificity (negative agreement) for the BinaxNOW were 53.3% and 100%, respectively, compared to the RT-PCR assay. The median cycle threshold (CT ) value in the specimens that had concordant positive BinaxNOW antigen results was significantly lower than that of specimens that were discordant (CT of 17.6 versus 29.6; P < 0.001). In individuals with presumably high viral loads (CT of <23.0), a 95.8% positive agreement was observed between the RT-PCR assay and BinaxNOW. Due to the possibility of false-negative results, caution must be taken when utilizing rapid antigen testing for screening asymptomatic individuals.