Your browser doesn't support javascript.
loading
Computed tomography-guided cutting needle biopsy for lung nodules: A comparative study between low-dose and standard dose protocols.
Zhang, Hui-Mei; Huo, Xiao-Bing; Wang, Hua-Long; Zhang, Xiao; Fu, Yu-Fei.
Afiliação
  • Zhang HM; Department of Radiology, Binzhou People's Hospital, Binzhou, No. 661 No. 7 Huanghe Road, Binzhou.
  • Huo XB; Department of Radiology, Binzhou People's Hospital, Binzhou, No. 661 No. 7 Huanghe Road, Binzhou.
  • Wang HL; Department of Radiology, Binzhou People's Hospital, Binzhou, No. 661 No. 7 Huanghe Road, Binzhou.
  • Zhang X; Department of Radiology, Binzhou People's Hospital, Binzhou, No. 661 No. 7 Huanghe Road, Binzhou.
  • Fu YF; Department of Radiology, Xuzhou Central Hospital, 199 Jiefang Road, Xuzhou, Jiangsu, China.
Medicine (Baltimore) ; 100(3): e24001, 2021 Jan 22.
Article em En | MEDLINE | ID: mdl-33545994
ABSTRACT: We aim to compare the diagnostic accuracy, safety, and radiation exposure between low-dose and standard-dose computed tomography (CT)-guided cutting needle biopsy (CNB) for lung nodules.From January 2016 to August 2017, all consecutive patients admitted with lung nodule underwent low-dose or standard-dose CT-guided CNB procedure in our center. Diagnostic accuracy and radiation dose were compared.A total of 67 and 69 patients who underwent low-dose and standard-dose CT-guided CNB procedure were included in this study. Each patient underwent CT-guided CNB for 1 nodule. The technical success rates were 100% in both groups. The sensitivity, specificity, and overall diagnostic accuracy were 97.7%, 100%, and 98.5% for low-dose group and 91.5%, 100%, and 94.2% for standard-dose group. There was no significant difference in diagnostic accuracy (P = .380) between 2 groups. Pneumothorax was found in 8 and 15 patients in the low-dose and standard-dose groups, respectively (11.9% vs 21.7%, P = .127). Hemoptysis was found in 10 and 10 patients in the low-dose and standard-dose groups, respectively (14.9% vs 14.5%, P = .943). The mean dose-length product was 38.2 ±â€Š17.2 mGy-cm and 375.3 ±â€Š115.7 mGy-cm in the low-dose and standard-dose groups (P < .001). The mean dose-length product was 38.2 ±â€Š17.2 mGy-cm and 375.3 ±â€Š115.7 mGy-cm in the low-dose and standard-dose groups, respectively (P < .001). The mean effective dose was 0.5 ±â€Š0.2 mSv and 5.3 ±â€Š1.6 mSv in the low-dose and standard-dose groups, respectively (P < .001).Low-dose CT-guided CNB of lung nodules significantly decreased radiation dose compared with standard-dose CT. The low-dose protocol could provide similar diagnostic accuracy and safety as standard-dose CT-guided CNB for lung nodules.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Biópsia por Agulha / Tomografia Computadorizada por Raios X / Detecção Precoce de Câncer / Biópsia Guiada por Imagem / Neoplasias Pulmonares Tipo de estudo: Diagnostic_studies / Etiology_studies / Guideline / Observational_studies / Screening_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Biópsia por Agulha / Tomografia Computadorizada por Raios X / Detecção Precoce de Câncer / Biópsia Guiada por Imagem / Neoplasias Pulmonares Tipo de estudo: Diagnostic_studies / Etiology_studies / Guideline / Observational_studies / Screening_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article