Your browser doesn't support javascript.
loading
Optimization of orbital retraction during endoscopic transorbital approach via quantitative measurement of the intraocular pressure - [SevEN 006].
Kim, Woohyun; Moon, Ju Hyung; Kim, Eui Hyun; Hong, Chang-Ki; Han, Jisang; Hong, Je Beom.
Afiliação
  • Kim W; Department of Neurosurgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
  • Moon JH; Department of Neurosurgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
  • Kim EH; Department of Neurosurgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
  • Hong CK; Department of Neurosurgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
  • Han J; Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Hong JB; Department of Neurosurgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, 29 Saemunan-ro, Jongno-gu, Seoul, 03181, Korea. jebeomhong@gmail.com.
BMC Ophthalmol ; 21(1): 76, 2021 Feb 08.
Article em En | MEDLINE | ID: mdl-33557770
ABSTRACT

BACKGROUND:

Increased use of the transorbital approach (TOA) warrants greater understanding of the risk of increased intraocular pressure (IOP) and intraorbital pressure (IORP) due to orbital compression. We aimed to investigate the changes in IOP and IORP in response to orbital retraction in TOA and establish a method for the continuous measurement of intraoperative IORP.

METHODS:

We assessed nine patients who underwent TOA surgery from January 2017 to December 2019, in addition to five cadavers. IORP and IOP were measured using a cannula needle monitor, tonometer, cuff manometer, and micro strain gauge monitor.

RESULTS:

In all nine clinical cases and five cadavers, increased physical compression of the orbit increased the IOP and IORP in a curvilinear pattern. In clinical cases, when the orbit was compressed 1.5 cm from the lateral margin in the sagittal plane, the mean IOP and IORP were 25.4 ± 5.2 mmHg and 14 ± 9.2 mmH2O, respectively. The IORP satisfactorily reflected the IOP (Pearson correlation coefficient = 0.824, p < 0.001).

CONCLUSION:

We measured IOP and IORP simultaneously during orbital compression to gain basic information on pressure changes. In clinical cases, the change in the IOP could be conveniently and noninvasively monitored using continuous IORP measurements.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glaucoma / Pressão Intraocular Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glaucoma / Pressão Intraocular Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article