Your browser doesn't support javascript.
loading
Kidney function monitoring to prevent 5-aminosalicylic acid nephrotoxicity: What the gastroenterologist should know.
Guillo, Lucas; D'Amico, Ferdinando; Achit, Hamza; Ayav, Carole; Guillemin, Francis; Danese, Silvio; Frimat, Luc; Peyrin-Biroulet, Laurent.
Afiliação
  • Guillo L; Department of Gastroenterology and Inserm NGERE U1256, University Hospital of Nancy, University of Lorraine, Vandoeuvre-lès-Nancy, France; Department of Gastroenterology, University Hospital of Marseille Nord, University of Aix-Marseille, Marseille, France.
  • D'Amico F; Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy.
  • Achit H; Inserm, CIC-1433 Clinical Epidemiology, University Hospital of Nancy, Université de Lorraine, Vandœuvre-Lès-Nancy, France.
  • Ayav C; Inserm, CIC-1433 Clinical Epidemiology, University Hospital of Nancy, Université de Lorraine, Vandœuvre-Lès-Nancy, France.
  • Guillemin F; Inserm, CIC-1433 Clinical Epidemiology, University Hospital of Nancy, Université de Lorraine, Vandœuvre-Lès-Nancy, France.
  • Danese S; Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy; IBD center, Department of Gastroenterology, Humanitas Clinical and Research Center - IRCCS, Rozzano, Milan, Italy.
  • Frimat L; Inserm, CIC-1433 Clinical Epidemiology, University Hospital of Nancy, Université de Lorraine, Vandœuvre-Lès-Nancy, France; Department of Nephrology, University Hospital of Nancy, Vandoeuvre-lès-Nancy, France.
  • Peyrin-Biroulet L; Department of Gastroenterology and Inserm NGERE U1256, University Hospital of Nancy, University of Lorraine, Vandoeuvre-lès-Nancy, France. Electronic address: peyrinbiroulet@gmail.com.
Dig Liver Dis ; 53(6): 691-696, 2021 Jun.
Article em En | MEDLINE | ID: mdl-33563584
BACKGROUND: The kidney function monitoring is recommended in routine practice to detect 5-aminosalicylic acid (5-ASA) related nephrotoxicity, although is not standardized. The optimal monitoring is unknown, especially the best timing and which tests to perform. We summarized why, how, and when to perform the monitoring for patients treated with 5-ASA and provided an overview of the current guidelines on this topic. METHOD: Relevant studies on this topic were searched in PubMed, Embase, and Web of Science databases from July to August 2020. RESULTS: Serum creatinine, the estimated glomerular filtration rate, and 24-h proteinuria are the 3 main tests used for the monitoring in daily practice. Regarding the timing, several monitoring strategies have been proposed and guidelines are available too, but they provide conflicting information. To date, there is no medical evidence-based that one strategy is better than another. Comorbidities, chronic renal disease, use of nephrotoxic drugs or concomitant steroid therapy also impact the nephrotoxicity risk. Based on the literature review we proposed a kidney function monitoring strategy to guide physicians in clinical practice. CONCLUSION: A baseline assessment should be performed in all patients treated with 5-ASA. The monitoring should be carried out according to the other nephrotoxic factors. A tight monitoring may reduce morbidity and mortality of drug nephrotoxicity.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Colite Ulcerativa / Anti-Inflamatórios não Esteroides / Mesalamina / Monitorização Fisiológica Tipo de estudo: Guideline / Systematic_reviews Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Colite Ulcerativa / Anti-Inflamatórios não Esteroides / Mesalamina / Monitorização Fisiológica Tipo de estudo: Guideline / Systematic_reviews Idioma: En Ano de publicação: 2021 Tipo de documento: Article