Your browser doesn't support javascript.
loading
Surrogate based continuous noninvasive blood pressure measurement.
Pielmus, Alexandru-Gabriel; Mühlstef, Jens; Bresch, Erik; Glos, Martin; Jungen, Christiane; Mieke, Stefan; Orglmeister, Reinhold; Schulze, Andreas; Stender, Birgit; Voigt, Verena; Zaunseder, Sebastian.
Afiliação
  • Pielmus AG; Electronics and Medical Signal Processing, Technical University of Berlin, Berlin, Germany.
  • Mühlstef J; Research Group 'Patient Care Solutions', Philips Research Europe, Eindhoven, The Netherlands.
  • Bresch E; Research Group 'Patient Care Solutions', Philips Research Europe, Eindhoven, The Netherlands.
  • Glos M; Interdisciplinary Center of Sleep Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany.
  • Jungen C; Klinik und Poliklinik für Kardiologie, Universitäres Herz- und Gefäßzentrum UKE Hamburg, Hamburg, Germany.
  • Mieke S; Physikalisch-Technische Bundesanstalt, Berlin, Germany.
  • Orglmeister R; Electronics and Medical Signal Processing, Technical University of Berlin, Berlin, Germany.
  • Schulze A; Research Group 'Patient Care Solutions', Philips Research Europe, Eindhoven, The Netherlands.
  • Stender B; Drägerwerk AG & Co KgaA, Lübeck, Germany.
  • Voigt V; Klinik für Anästhesiologie, Sektion Medizintechnik, Uniklinik RWTH Aachen, Aachen, Germany.
  • Zaunseder S; Technical University of Dresden, Dresden, Germany.
Biomed Tech (Berl) ; 66(3): 231-245, 2021 Jun 25.
Article em En | MEDLINE | ID: mdl-33565285
ABSTRACT
Arterial blood pressure is one of the most often measured vital parameters in clinical practice. State-of-the-art noninvasive ABP measurement technologies have noticeable limitations and are mainly based on uncomfortable techniques of complete or partial arterial occlusion by cuffs. Most commonplace devices provide only intermittent measurements, and continuous systems are bulky and difficult to apply correctly for nonprofessionals. Continuous cuffless ABP measurements are still an unmet clinical need and a topic of ongoing research, with only few commercially available devices. This paper discusses surrogate-based noninvasive blood pressure measurement techniques. It covers measurement methods of continuously and noninvasively inferring BP from surrogate signals without applying external pressures, except for reference or initialization purposes. The BP is estimated by processing signal features, so called surrogates, which are modulated by variations of BP. Discussed techniques include well-known approaches such as pulse transit time and pulse arrival time techniques, pulse wave analysis or combinations thereof. Despite a long research history, these methods have not found widespread use in clinical and ambulatory practice, in part due to technical limitations and the lack of a standardized regulatory framework. This work summarizes findings from an invited workshop of experts in the fields covering clinical expertise, engineering aspects, commercialization and standardization issues. The goal is to provide an application driven outlook, starting with clinical needs, and extending to technical actuality. It provides an outline of recommended research directions and includes a detailed overview of clinical use case scenarios for these technologies, opportunities, and limitations.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pressão Sanguínea / Análise de Onda de Pulso Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pressão Sanguínea / Análise de Onda de Pulso Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article