Your browser doesn't support javascript.
loading
Comparison of three freeware software packages for 18F-FDG PET texture feature calculation.
Larobina, Michele; Megna, Rosario; Solla, Raffaele.
Afiliação
  • Larobina M; Institute of Biostructures and Bioimaging, National Research Council (CNR), Via Tommaso de Amicis, 95, 80145, Napoli, Italy.
  • Megna R; Institute of Biostructures and Bioimaging, National Research Council (CNR), Via Tommaso de Amicis, 95, 80145, Napoli, Italy. rosario.megna@cnr.it.
  • Solla R; Institute of Biostructures and Bioimaging, National Research Council (CNR), Via Tommaso de Amicis, 95, 80145, Napoli, Italy.
Jpn J Radiol ; 39(7): 710-719, 2021 Jul.
Article em En | MEDLINE | ID: mdl-33595789
ABSTRACT

PURPOSE:

To compare texture feature estimates obtained from 18F-FDG-PET images using three different software packages.

METHODS:

PET images from 15 patients with head and neck cancer were processed with three different freeware software CGITA, LIFEx, and Metavol. For each lesion, 38 texture features were extracted from each software package. To evaluate the statistical agreement among the features across packages a non-parametric Kruskal-Wallis test was used. Differences in the features between each couple of software were assessed using a subsequent Dunn test. Correlation between texture features was evaluated via the Spearman coefficient.

RESULTS:

Twenty-three of 38 features showed a significant agreement across the three software (P < 0.05). The agreement was better between LIFEx vs. Metavol (36 of 38) and worse between CGITA and Metavol (24 of 38), and CGITA vs. LIFEx (23 of 38). All features resulted correlated (ρ > = 0.70, P < 0.001) in comparing LIFEx vs. Metavol. Seven of 38 features were found not in agreement and slightly or not correlated (ρ < 0.70, P < 0.001) in comparing CGITA vs. LIFEx, and CGITA vs. Metavol.

CONCLUSION:

Some texture discrepancies across software packages exist. Our findings reinforce the need to continue the standardization process, and to succeed in building a reference dataset to be used for comparisons.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Validação de Programas de Computador / Intensificação de Imagem Radiográfica / Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada / Neoplasias de Cabeça e Pescoço Tipo de estudo: Evaluation_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Validação de Programas de Computador / Intensificação de Imagem Radiográfica / Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada / Neoplasias de Cabeça e Pescoço Tipo de estudo: Evaluation_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article