Your browser doesn't support javascript.
loading
Stereospecific Response of E/Z-isomers of N-Nitrososarcosine in LC-ESI-MS/MS.
Werneth, Madeleine; Pani, Jutta; Hofbauer, Ludwig; Pummer, Stefan; Weber, Maria-Theres; Pour, Georg; Kählig, Hanspeter; Mayer-Helm, Bernhard; Stepan, Herwig.
Afiliação
  • Werneth M; Ökolab Gesellschaft für Umweltanalytik, A Member of the Japan Tobacco International Group of Companies, Hasnerstraße 127, Vienna 1160, Austria.
  • Pani J; Ökolab Gesellschaft für Umweltanalytik, A Member of the Japan Tobacco International Group of Companies, Hasnerstraße 127, Vienna 1160, Austria.
  • Hofbauer L; Ökolab Gesellschaft für Umweltanalytik, A Member of the Japan Tobacco International Group of Companies, Hasnerstraße 127, Vienna 1160, Austria.
  • Pummer S; Ökolab Gesellschaft für Umweltanalytik, A Member of the Japan Tobacco International Group of Companies, Hasnerstraße 127, Vienna 1160, Austria.
  • Weber MT; Ökolab Gesellschaft für Umweltanalytik, A Member of the Japan Tobacco International Group of Companies, Hasnerstraße 127, Vienna 1160, Austria.
  • Pour G; Ökolab Gesellschaft für Umweltanalytik, A Member of the Japan Tobacco International Group of Companies, Hasnerstraße 127, Vienna 1160, Austria.
  • Kählig H; Department of Organic Chemistry, University of Vienna, Währinger Straße 38, Vienna 1090, Austria.
  • Mayer-Helm B; Ökolab Gesellschaft für Umweltanalytik, A Member of the Japan Tobacco International Group of Companies, Hasnerstraße 127, Vienna 1160, Austria.
  • Stepan H; Ökolab Gesellschaft für Umweltanalytik, A Member of the Japan Tobacco International Group of Companies, Hasnerstraße 127, Vienna 1160, Austria.
J Chromatogr Sci ; 59(9): 813-822, 2021 Sep 29.
Article em En | MEDLINE | ID: mdl-33618358
ABSTRACT
The carcinogenic compound N-nitrososarcosine (NSAR) is found in foods and tobacco products, and its quantification is of great interest. Although the presence of two stereoisomers, E- and Z-NSAR, is well-known, individual investigation of the isomers has not been reported so far. The present study by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) reveals that (i) the mass spectrometric responses of the isomers differ by a factor of approximately two and (ii) the isomer ratio is unstable in freshly prepared standard solutions. As a consequence, NSAR concentrations determined by LC-ESI-MS/MS are biased if those facts are not taken into account. The method described here overcomes the difficulty of stereospecific response by adjusting the isomer ratio and was applied to 100 tobacco products and fully validated for moist and dry snuff reference materials showing expanded measurement uncertainties of ~20% and limits of quantification of ~20 ng/g.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article