Your browser doesn't support javascript.
loading
Whole-brain quantitative CEST MRI at 7T using parallel transmission methods and B1+ correction.
Liebert, Andrzej; Tkotz, Katharina; Herrler, Jürgen; Linz, Peter; Mennecke, Angelika; German, Alex; Liebig, Patrick; Gumbrecht, Rene; Schmidt, Manuel; Doerfler, Arnd; Uder, Michael; Zaiss, Moritz; Nagel, Armin M.
Afiliação
  • Liebert A; Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Tkotz K; Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Herrler J; Department of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Linz P; Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Mennecke A; Department of Nephrology and Hypertension, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • German A; Department of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Liebig P; Department of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Gumbrecht R; Siemens Healthcare GmbH, Erlangen, Germany.
  • Schmidt M; Siemens Healthcare GmbH, Erlangen, Germany.
  • Doerfler A; Department of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Uder M; Department of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Zaiss M; Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Nagel AM; Department of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
Magn Reson Med ; 86(1): 346-362, 2021 07.
Article em En | MEDLINE | ID: mdl-33634505

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Imageamento por Ressonância Magnética Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Imageamento por Ressonância Magnética Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article