Your browser doesn't support javascript.
loading
Clear and Consistent Imaging of Hippocampal Internal Architecture With High Resolution Multiple Image Co-registration and Averaging (HR-MICRA).
Ver Hoef, Lawrence; Deshpande, Hrishikesh; Cure, Joel; Selladurai, Goutham; Beattie, Julia; Kennedy, Richard E; Knowlton, Robert C; Szaflarski, Jerzy P.
Afiliação
  • Ver Hoef L; Department of Neurology, The University of Alabama at Birmingham, Birmingham, AL, United States.
  • Deshpande H; Department of Biomedical Engineering, The University of Alabama at Birmingham, Birmingham, AL, United States.
  • Cure J; Neurology Service, Birmingham VA Medical Center, Birmingham, AL, United States.
  • Selladurai G; Department of Radiology, The University of Alabama at Birmingham, Birmingham, AL, United States.
  • Beattie J; Department of Radiology, The University of Alabama at Birmingham, Birmingham, AL, United States.
  • Kennedy RE; Department of Neurology, The University of Alabama at Birmingham, Birmingham, AL, United States.
  • Knowlton RC; Division of Behavioral Medicine and Clinical Psychology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, United States.
  • Szaflarski JP; Division of Gerontology, Geriatrics, and Palliative Care, Department of Medicine, The University of Alabama at Birmingham, Birmingham, AL, United States.
Front Neurosci ; 15: 546312, 2021.
Article em En | MEDLINE | ID: mdl-33642971
ABSTRACT
Magnetic resonance imaging of hippocampal internal architecture (HIA) at 3T is challenging. HIA is defined by layers of gray and white matter that are less than 1 mm thick in the coronal plane. To visualize HIA, conventional MRI approaches have relied on sequences with high in-plane resolution (≤0.5 mm) but comparatively thick slices (2-5 mm). However, thicker slices are prone to volume averaging effects that result in loss of HIA clarity and blurring of the borders of the hippocampal subfields in up to 61% of slices as has been reported. In this work we describe an approach to hippocampal imaging that provides consistently high HIA clarity using a commonly available sequence and post-processing techniques that is flexible and may be applicable to any MRI platform. We refer to this approach as High Resolution Multiple Image Co-registration and Averaging (HR-MICRA). This approach uses a variable flip angle turbo spin echo sequence to repeatedly acquire a whole brain T2w image volume with high resolution in three dimensions in a relatively short amount of time, and then co-register the volumes to correct for movement and average the repeated scans to improve SNR. We compared the averages of 4, 9, and 16 individual scans in 20 healthy controls using a published HIA clarity rating scale. In the body of the hippocampus, the proportion of slices with good or excellent HIA clarity was 90%, 83%, and 67% for the 16x, 9x, and 4x HR-MICRA images, respectively. Using the 4x HR-MICRA images as a baseline, the 9x HR-MICRA images were 2.6 times and 16x HR-MICRA images were 3.2 times more likely to have high HIA ratings (p < 0.001) across all hippocampal segments (head, body, and tail). The thin slices of the HR-MICRA images allow reformatting in any plane with clear visualization of hippocampal dentation in the sagittal plane. Clear and consistent visualization of HIA will allow application of this technique to future hippocampal structure research, as well as more precise manual or automated segmentation.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article