Your browser doesn't support javascript.
loading
Study of an Online Monitoring Adaptive System for an Injection Molding Process Based on a Nozzle Pressure Curve.
Fan-Jiang, Jia-Chen; Su, Chi-Wei; Liou, Guan-Yan; Hwang, Sheng-Jye; Lee, Huei-Huang; Peng, Hsin-Shu; Chu, Hsiao-Yeh.
Afiliação
  • Fan-Jiang JC; Department of Mechanical Engineering, National Cheng Kung University, Tainan 700, Taiwan.
  • Su CW; Department of Mechanical Engineering, National Cheng Kung University, Tainan 700, Taiwan.
  • Liou GY; Department of Mechanical Engineering, National Cheng Kung University, Tainan 700, Taiwan.
  • Hwang SJ; Department of Mechanical Engineering, National Cheng Kung University, Tainan 700, Taiwan.
  • Lee HH; Department of Engineering Science, National Cheng Kung University, Tainan 700, Taiwan.
  • Peng HS; Department of Mechanical and Computer-Aided Engineering, Feng Chia University, Taichung 400, Taiwan.
  • Chu HY; Department of Mechanical Engineering, Kun Shan University, Tainan 700, Taiwan.
Polymers (Basel) ; 13(4)2021 Feb 13.
Article em En | MEDLINE | ID: mdl-33668539
Injection molding is a popular process for the mass production of polymer products, but due to the characteristics of the injection process, there are many factors that will affect the product quality during the long fabrication processes. In this study, an adaptive adjustment system was developed by C++ programming to adjust the V/P switchover point and injection speed during the injection molding process in order to minimize the variation of the product weight. Based on a series of preliminary experiments, it was found that the viscosity index and peak pressure had a strong correlation with the weight of the injection-molded parts. Therefore, the viscosity index and peak pressure are used to guide the adjustment in the presented control system, and only one nozzle pressure sensor is used in the system. The results of the preliminary experiments indicate that the reduction of the packing time and setting enough clamping force can decrease the variation of the injected weight without turning on the adaptive control system; meanwhile, the master pressure curve obtained from the preliminary experiment was used as the control target of the system. With this system, the variation of the product weight and coefficient of variation (CV) of the product weight can be decreased to 0.21 and 0.05%, respectively.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article