Your browser doesn't support javascript.
loading
Effect of computer-assisted design and manufacturing cutting and drilling guides accompanied with pre-bent titanium plates on the correction of skeletal class II malocclusion: a randomized controlled trial.
Liu, S; Li, J; Xu, C; Zhou, H; Liao, C; Fei, W; Luo, E.
Afiliação
  • Liu S; State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
  • Li J; Shanghai Stomatological Hospital, Fudan University, Shanghai, China.
  • Xu C; Department of Stomatology, Sichuan Academy of Medical Science and Sichuan Provincial People's Hospital, Chengdu, China.
  • Zhou H; Department of Stomatology, Sichuan Academy of Medical Science and Sichuan Provincial People's Hospital, Chengdu, China.
  • Liao C; Department of Stomatology, Sichuan Academy of Medical Science and Sichuan Provincial People's Hospital, Chengdu, China.
  • Fei W; Department of Stomatology, Sichuan Academy of Medical Science and Sichuan Provincial People's Hospital, Chengdu, China.
  • Luo E; State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China. Electronic address: Luoen521125@sina.com.
Int J Oral Maxillofac Surg ; 50(10): 1320-1328, 2021 Oct.
Article em En | MEDLINE | ID: mdl-33685740
ABSTRACT
This study was performed to assess the effect of correcting skeletal class II malocclusion based on the application of computer-assisted design and manufacturing (CAD/CAM) cutting and drilling guides accompanied with pre-bent titanium plates. Fifty patients with skeletal class II malocclusion were recruited into this prospective randomized controlled clinical trial and assigned to two groups. Patients underwent bilateral sagittal split ramus osteotomy directed by CAD/CAM cutting and drilling guides accompanied with pre-bent titanium plates (group A) or CAD/CAM splints (group B). Postoperative assessments were performed. Differences between the virtually simulated and postoperative models were measured. Patients in both groups had a satisfactory occlusion and appearance. More accurate repositioning of the proximal segment was found in group A than in group B when comparing linear and angular differences to reference planes; however, no significant difference was revealed for the distal segment. In conclusion, CAD/CAM cutting and drilling guides with pre-bent titanium plates can provide considerable surgical accuracy for the positional control of the proximal segments in bilateral sagittal split ramus osteotomy for the correction of skeletal class II deformities.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cirurgia Assistida por Computador / Procedimentos Cirúrgicos Ortognáticos / Má Oclusão Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cirurgia Assistida por Computador / Procedimentos Cirúrgicos Ortognáticos / Má Oclusão Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article