Your browser doesn't support javascript.
loading
Microcapsule-based biosensor containing catechol for the reagent-free inhibitive detection of benzoic acid by tyrosinase.
Nedellec, Yannig; Gondran, Chantal; Gorgy, Karine; Mc Murtry, Stefan; Agostini, Pierre; Elmazria, Omar; Cosnier, Serge.
Afiliação
  • Nedellec Y; Université Grenoble Alpes, DCM UMR 5250, F-38000, Grenoble, France; CNRS, DCM UMR 5250, F-38000, Grenoble, France.
  • Gondran C; Université Grenoble Alpes, DCM UMR 5250, F-38000, Grenoble, France; CNRS, DCM UMR 5250, F-38000, Grenoble, France.
  • Gorgy K; Université Grenoble Alpes, DCM UMR 5250, F-38000, Grenoble, France; CNRS, DCM UMR 5250, F-38000, Grenoble, France.
  • Mc Murtry S; Université de Lorraine Institut Jean Lamour, UMR 7198, F-54000, Nancy, France; CNRS, Institut Jean Lamour, UMR, 7198, F-54000, Nancy, France.
  • Agostini P; Université de Lorraine Institut Jean Lamour, UMR 7198, F-54000, Nancy, France; CNRS, Institut Jean Lamour, UMR, 7198, F-54000, Nancy, France.
  • Elmazria O; Université de Lorraine Institut Jean Lamour, UMR 7198, F-54000, Nancy, France; CNRS, Institut Jean Lamour, UMR, 7198, F-54000, Nancy, France.
  • Cosnier S; Université Grenoble Alpes, DCM UMR 5250, F-38000, Grenoble, France; CNRS, DCM UMR 5250, F-38000, Grenoble, France. Electronic address: Serge.Cosnier@univ-grenoble-alpes.fr.
Biosens Bioelectron ; 180: 113137, 2021 May 15.
Article em En | MEDLINE | ID: mdl-33690099
ABSTRACT
A biosensor based on the release of the enzyme substrate from its structure was developed for the inhibitive detection of benzoic acid. A polyurethane support comprising two perforated microcapsules (800 µm in diameter) filled with methylene blue as a model compound and covered with a conductive deposit of multiwalled carbon nanotubes, continuously released this stored dye for 24 h. An increase in methylene blue concentration of 0.5-0.75 µmol L-1 h-1 and 1.5-2 µmol L-1 h-1, in the presence and absence of the multiwalled carbon nanotube coating, respectively, was demonstrated by UV-vis spectroscopy in a 2 mL UV cuvette. The same configuration with microcapsules filled with catechol was modified by a laponite clay coating containing tyrosinase enzyme. The resulting biosensor exhibits a constant cathodic current at -0.155 V vs AgCl/Ag, due to the reduction of the ortho-quinone produced enzymatically from the released catechol. The detection of benzoic acid was recorded from the decrease in cathodic current due to its inhibiting action on the tyrosinase activity. Reagentless biosensors based on different deposited quantity of tyrosinase (100, 200, 400 and 600 µg) were investigated for the detection of catechol and applied to the detection of benzoic acid as inhibitor. The best performance was obtained with the 400 µg-based configuration, namely a detection limit of 0.4 µmol L-1 and a sensitivity of 228 mA L mol-1. After the inhibition process, the biosensors recover 97-100% of their activity towards catechol, confirming a reversible inhibition by benzoic acid.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanotubos de Carbono Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanotubos de Carbono Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article