Your browser doesn't support javascript.
loading
Comparison of Two Methods for Presurgical Volumetric Evaluation of Alveolar Cleft Bone Defects Using Computer-Aided Engineering.
Liu, Bing; Yin, Ning B; Xiao, Ran; Li, Hai D; Chen, Shu X; Li, Si L; Wang, Yong Q.
Afiliação
  • Liu B; Center for Cleft Lip and Palate Treatment, Plastic Surgery Hospital.
  • Yin NB; Center for Cleft Lip and Palate Treatment, Plastic Surgery Hospital.
  • Xiao R; Research Center, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Li HD; Center for Cleft Lip and Palate Treatment, Plastic Surgery Hospital.
  • Chen SX; Center for Cleft Lip and Palate Treatment, Plastic Surgery Hospital.
  • Li SL; Center for Cleft Lip and Palate Treatment, Plastic Surgery Hospital.
  • Wang YQ; Center for Cleft Lip and Palate Treatment, Plastic Surgery Hospital.
J Craniofac Surg ; 32(2): 477-481, 2021.
Article em En | MEDLINE | ID: mdl-33704964
ABSTRACT
ABSTRACT Precise volumetric evaluation of the alveolar cleft facilitates accurate preparation of bone substitutes and reduces donor site morbidity. This study investigates 2 advanced presurgical volumetric assessment methods that use computer-aided engineering (CAE) software. Preoperative computed tomography (CT) scans from 20 unilateral alveolar cleft patients undergoing secondary alveolar bone grafting (SABG) were analyzed by CAE software. Cleft defect volumes were calculated using the mirror-reversed technique and the subtraction method. The mirror-reversed technique determines defect volume by reversing the noncleft side to the cleft side. The subtraction method determines defect volume by subtracting a mask of the preoperative cleft from a mask generated after simulated cleft filling. The mean defect volumes and calculation times of the mirror-reversed technique (1.27 ±â€Š0.35 cm3; 11.80 ±â€Š1.79 seconds) and the subtractive method (1.23 ±â€Š0.32 cm3; 9.43 ±â€Š1.35 seconds) did not differ significantly. In Bland-Altman analysis the 2 methods were equivalent for alveolar cleft defect assessment. Both methods exhibited acceptable interobserver reliability, high precision, clinical convenience, time efficiency, and high reproducibility, and can serve as valuable tools for the planning and execution of SABG. The subtraction method has broader potential applicability and can simulate intraoperative bone grafting more effectively.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fenda Labial / Fissura Palatina / Enxerto de Osso Alveolar Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fenda Labial / Fissura Palatina / Enxerto de Osso Alveolar Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article