Your browser doesn't support javascript.
loading
Global and regional cardiac dysfunction quantified by 18F-FDG PET scans can predict ventricular arrhythmia in patients with implantable cardioverter defibrillator.
Jing, Ran; Sun, Xiao-Xin; Hua, Wei; Chen, Liang; Yang, Sheng-Wen; Hu, Yi-Ran; Zhang, Ni-Xiao; Cai, Min-Si; Gu, Min; Niu, Hong-Xia; Zhang, Shu.
Afiliação
  • Jing R; State Key Laboratory of Cardiovascular Disease, The Cardiac Arrhythmia Center, Fu Wai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No. 167 Bei Li Shi Road, Xicheng District, Beijing, 100037, People's Republic of China.
  • Sun XX; Department of Nuclear Medicine, State Key Laboratory of Cardiovascular Disease, Fu Wai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, People's Republic of China.
  • Hua W; State Key Laboratory of Cardiovascular Disease, The Cardiac Arrhythmia Center, Fu Wai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No. 167 Bei Li Shi Road, Xicheng District, Beijing, 100037, People's Republic of China. drhuaweifw@sina.com.
  • Chen L; State Key Laboratory of Cardiovascular Disease, The Cardiac Arrhythmia Center, Fu Wai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No. 167 Bei Li Shi Road, Xicheng District, Beijing, 100037, People's Republic of China.
  • Yang SW; State Key Laboratory of Cardiovascular Disease, The Cardiac Arrhythmia Center, Fu Wai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No. 167 Bei Li Shi Road, Xicheng District, Beijing, 100037, People's Republic of China.
  • Hu YR; State Key Laboratory of Cardiovascular Disease, The Cardiac Arrhythmia Center, Fu Wai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No. 167 Bei Li Shi Road, Xicheng District, Beijing, 100037, People's Republic of China.
  • Zhang NX; State Key Laboratory of Cardiovascular Disease, The Cardiac Arrhythmia Center, Fu Wai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No. 167 Bei Li Shi Road, Xicheng District, Beijing, 100037, People's Republic of China.
  • Cai MS; State Key Laboratory of Cardiovascular Disease, The Cardiac Arrhythmia Center, Fu Wai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No. 167 Bei Li Shi Road, Xicheng District, Beijing, 100037, People's Republic of China.
  • Gu M; State Key Laboratory of Cardiovascular Disease, The Cardiac Arrhythmia Center, Fu Wai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No. 167 Bei Li Shi Road, Xicheng District, Beijing, 100037, People's Republic of China.
  • Niu HX; State Key Laboratory of Cardiovascular Disease, The Cardiac Arrhythmia Center, Fu Wai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No. 167 Bei Li Shi Road, Xicheng District, Beijing, 100037, People's Republic of China.
  • Zhang S; State Key Laboratory of Cardiovascular Disease, The Cardiac Arrhythmia Center, Fu Wai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No. 167 Bei Li Shi Road, Xicheng District, Beijing, 100037, People's Republic of China.
J Nucl Cardiol ; 28(2): 464-477, 2021 04.
Article em En | MEDLINE | ID: mdl-33751472
ABSTRACT

BACKGROUND:

A low appropriate therapy rate indicates that a minority of patients will benefit from their implantable cardioverter defibrillator (ICD). Quantitative measurements from 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET) may predict ventricular arrhythmia (VA) occurrence after ICD placement.

METHODS:

We performed a prospective observational study and recruited patients who required ICD placement. Pre-procedure image scans were performed. Patients were followed up for VA occurrence. Associations between image results and VA were analyzed.

RESULTS:

In 51 patients (33 males, 53.9 ± 17.2 years) analyzed, 17 (33.3%) developed VA. Compared with patients without VA, patients with VA had significantly larger values in scar area (17.7 ± 12.4% vs. 7.0 ± 7.9%), phase standard deviation (51.4° ± 14.0° vs. 34.0° ± 15.0°), bandwidth (172.9° ± 39.8° vs. 128.7° ± 49.9°), sum thickening score (STS, 29.5 ± 11.1 vs. 17.8 ± 13.2), and sum motion score (42.9 ± 11.5 vs. 33.0 ± 19.0). Cox regression analysis and receiver operating characteristic curve analysis showed that scar size, dyssynchrony, and STS were associated with VA occurrence (HR, 4.956, 95% CI 1.70-14.46).

CONCLUSION:

Larger left ventricular scar burden, increased dyssynchrony, and higher STS quantified by 18F-FDG PET may indicate a higher VA incidence after ICD placement.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Ventricular / Taquicardia Ventricular / Desfibriladores Implantáveis / Compostos Radiofarmacêuticos / Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons / Técnicas de Imagem Cardíaca Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Ventricular / Taquicardia Ventricular / Desfibriladores Implantáveis / Compostos Radiofarmacêuticos / Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons / Técnicas de Imagem Cardíaca Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article