Your browser doesn't support javascript.
loading
Using anthropometric measures to screen for obstructive sleep apnea in the Sleep Heart Health Study cohort.
Vana, Kimberly D; Silva, Graciela E; Carreon, Joseph D; Quan, Stuart F.
Afiliação
  • Vana KD; Edson College of Nursing and Health Innovation, Arizona State University, Phoenix, Arizona.
  • Silva GE; College of Nursing, University of Arizona, Tucson, Arizona.
  • Carreon JD; The Clovers' Leaves Limited Company, Tempe, Arizona.
  • Quan SF; Division of Sleep and Circadian Disorders, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts.
J Clin Sleep Med ; 17(8): 1635-1643, 2021 08 01.
Article em En | MEDLINE | ID: mdl-33779542
ABSTRACT
STUDY

OBJECTIVES:

To evaluate predictions of moderate to severe obstructive sleep apnea (MS-OSA) by the neck circumference/height ratio (NHR) and waist circumference/height ratio (WHR) and compare to the derived STOP-Bang Questionnaire (dSBQ) prediction.

METHODS:

Included were 6,167 participants from the Sleep Heart Health Study baseline evaluation who completed polysomnograms and had anthropometric measurements and data to compute proxy dSBQ item answers. The sample was divided randomly into derivation (n = 2,035) and validation (n = 4,132) subsets. The derivation sample was used to estimate the NHR and WHR cut points to detect MS-OSA; the validation sample was used to evaluate sensitivity and specificity.

RESULTS:

Mean age was 63.1 years, and 47.2% were men for the overall sample. In the derivation sample, a cut point ≥ 0.21 for NHR yielded a sensitivity of 92.0% and a specificity of 25.0%; a cut point ≥ 0.52 for WHR yielded a sensitivity of 91.2% and a specificity of 25.0% for MS-OSA. Using the validation sample, the NHR, WHR, and dSBQ areas under the receiver operator curves were 69.8%, 65.2%, and 70.5%, respectively, for MS-OSA. There was no statistical difference with listwise comparison of the NHR and dSBQ areas under the receiver operator curves (P = .997); however, there was a significant difference between the WHR and dSBQ areas under the receiver operator curves (P = .015) for MS-OSA.

CONCLUSIONS:

The NHR is a viable obstructive sleep apnea screening tool comparable to the dSBQ, independent of witnessed apneas and body mass index, that can be used for different body types. CITATION Vana KD, Silva GE, Carreon JD, Quan SF. Using anthropometric measures to screen for obstructive sleep apnea in the Sleep Heart Health Study cohort. J Clin Sleep Med. 2021;17(8)1635-1643.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Apneia Obstrutiva do Sono Tipo de estudo: Diagnostic_studies / Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Humans / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Apneia Obstrutiva do Sono Tipo de estudo: Diagnostic_studies / Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Humans / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article