Your browser doesn't support javascript.
loading
Development, Validation, and Comparison of Two Mass Spectrometry Methods (LC-MS/HRMS and LC-MS/MS) for the Quantification of Rituximab in Human Plasma.
Millet, Aurélien; Khoudour, Nihel; Lebert, Dorothée; Machon, Christelle; Terrier, Benjamin; Blanchet, Benoit; Guitton, Jérôme.
Afiliação
  • Millet A; Biochemistry and Pharmacology-Toxicology Laboratory, Lyon-Sud Hospital, Hospices Civils de Lyon, F-69495 Pierre Bénite, France.
  • Khoudour N; Inserm U1052, CNRS UMR5286 Cancer Research Center of Lyon, F-69000 Lyon, France.
  • Lebert D; Department of Pharmacokinetics and Pharmacochemistry, Cochin Hospital, AP-HP, CARPEM 75014 Paris, France.
  • Machon C; Promise Proteomics, 7 Parvis Louis Néel, F-38040 Grenoble, France.
  • Terrier B; Biochemistry and Pharmacology-Toxicology Laboratory, Lyon-Sud Hospital, Hospices Civils de Lyon, F-69495 Pierre Bénite, France.
  • Blanchet B; Inserm U1052, CNRS UMR5286 Cancer Research Center of Lyon, F-69000 Lyon, France.
  • Guitton J; Analytical Chemistry Laboratory, Faculty of Pharmacy ISPBL, University Lyon 1, F-69373 Lyon, France.
Molecules ; 26(5)2021 Mar 04.
Article em En | MEDLINE | ID: mdl-33806585
Rituximab is a chimeric immunoglobulin G1-kappa (IgG1κ) antibody targeting the CD20 antigen on B-lymphocytes. Its applications are various, such as for the treatment of chronic lymphoid leukemia or non-Hodgkin's lymphoma in oncology, and it can also be used in the treatment of certain autoimmune diseases. Several studies support the interest in therapeutic drug monitoring to optimize dosing regimens of rituximab. Thus, two different laboratories have developed accurate and reproductive methods to quantify rituximab in human plasma: one using liquid chromatography quadripolar tandem mass spectrometer (LC-MS/MS) and the other, liquid chromatography orbitrap tandem mass spectrometer (LC-MS/HRMS). For both assays, quantification was based on albumin depletion or IgG-immunocapture, surrogate peptide analysis, and full-length stable isotope-labeled rituximab. With LC-MS/MS, the concentration range was from 5 to 500 µg/mL, the within- and between-run precisions were <8.5%, and the limit of quantitation was 5 µg/mL. With LC-MS/HRMS, the concentration range was from 10 to 200 µg/mL, the within- and between-run accuracy were <11.5%, and the limit of quantitation was 2 µg/mL. Rituximab plasma concentrations from 63 patients treated for vasculitis were compared. Bland-Altman analysis and Passing-Bablok regression showed the interchangeability between these two methods. Overall, these methods were robust and reliable and could be applied to routine clinical samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vasculite / Cromatografia Líquida / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz / Espectrometria de Massas em Tandem / Rituximab / Antineoplásicos Imunológicos / Linfoma Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vasculite / Cromatografia Líquida / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz / Espectrometria de Massas em Tandem / Rituximab / Antineoplásicos Imunológicos / Linfoma Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article