Your browser doesn't support javascript.
loading
Measurement of L-shell emission from mid-Z targets under non-LTE conditions using Transmission Grating Spectrometer and DANTE power diagnostics.
Fraenkel, M; Ehrlich, Y; Shpilman, Z; Henis, Z; Frank, Y; Marley, E V; Pérez-Callejo, G; Emig, J; Heeter, R F; Liedahl, D A; Foord, M E; Schneider, M B.
Afiliação
  • Fraenkel M; Plasma Physics Department, Soreq NRC, Yavne 81800, Israel.
  • Ehrlich Y; Plasma Physics Department, Soreq NRC, Yavne 81800, Israel.
  • Shpilman Z; Plasma Physics Department, Soreq NRC, Yavne 81800, Israel.
  • Henis Z; Plasma Physics Department, Soreq NRC, Yavne 81800, Israel.
  • Frank Y; Lawrence Livermore National Laboratory, Livermore, California 94551, USA.
  • Marley EV; Lawrence Livermore National Laboratory, Livermore, California 94551, USA.
  • Pérez-Callejo G; Clarendon Laboratory-University of Oxford, Parks Road, Oxford OX1 3PU, United Kingdom.
  • Emig J; Lawrence Livermore National Laboratory, Livermore, California 94551, USA.
  • Heeter RF; Lawrence Livermore National Laboratory, Livermore, California 94551, USA.
  • Liedahl DA; Lawrence Livermore National Laboratory, Livermore, California 94551, USA.
  • Foord ME; Lawrence Livermore National Laboratory, Livermore, California 94551, USA.
  • Schneider MB; Lawrence Livermore National Laboratory, Livermore, California 94551, USA.
Rev Sci Instrum ; 92(3): 033502, 2021 Mar 01.
Article em En | MEDLINE | ID: mdl-33820003
ABSTRACT
In this work, we present the measurement of L-band emission from buried Sc/V targets in experiments performed at the OMEGA laser facility. The goal of these experiments was to study non-local thermodynamic equilibrium plasmas and benchmark atomic physics codes. The L-band emission was measured simultaneously by the time resolved DANTE power diagnostic and the recently fielded time integrated Soreq-Transmission Grating Spectrometer (TGS) diagnostic. The TGS measurement was used to support the spectral reconstruction process needed for the unfolding of the DANTE data. The Soreq-TGS diagnostic allows for broadband spectral measurement in the 120 eV-2000 eV spectral band, covering L- and M-shell emission of mid- and high-Z elements, with spectral resolution λ/Δλ = 8-30 and accuracy better than 25%. The Soreq-TGS diagnostic is compatible with ten-inch-manipulator platforms and can be used for a wide variety of high energy density physics, laboratory astrophysics, and inertial confinement fusion experiments.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article