Your browser doesn't support javascript.
loading
Serial Block-Face Scanning Electron Microscopy (SBF-SEM) of Biological Tissue Samples.
Courson, Justin A; Landry, Paul T; Do, Thao; Spehlmann, Eric; Lafontant, Pascal J; Patel, Nimesh; Rumbaut, Rolando E; Burns, Alan R.
Afiliação
  • Courson JA; College of Optometry, University of Houston; jacourso@central.uh.edu.
  • Landry PT; College of Optometry, University of Houston.
  • Do T; College of Optometry, University of Houston.
  • Spehlmann E; Department of Biology, DePauw University.
  • Lafontant PJ; Department of Biology, DePauw University.
  • Patel N; College of Optometry, University of Houston.
  • Rumbaut RE; Center for Translational Research on Inflammatory Diseases (CTRID), Michael E. DeBakey Veterans Affairs Medical Center; Children's Nutrition Center, Baylor College of Medicine.
  • Burns AR; College of Optometry, University of Houston; Children's Nutrition Center, Baylor College of Medicine.
J Vis Exp ; (169)2021 03 26.
Article em En | MEDLINE | ID: mdl-33843931
ABSTRACT
Serial block-face scanning electron microscopy (SBF-SEM) allows for the collection of hundreds to thousands of serially-registered ultrastructural images, offering an unprecedented three-dimensional view of tissue microanatomy. While SBF-SEM has seen an exponential increase in use in recent years, technical aspects such as proper tissue preparation and imaging parameters are paramount for the success of this imaging modality. This imaging system benefits from the automated nature of the device, allowing one to leave the microscope unattended during the imaging process, with the automated collection of hundreds of images possible in a single day. However, without appropriate tissue preparation cellular ultrastructure can be altered in such a way that incorrect or misleading conclusions might be drawn. Additionally, images are generated by scanning the block-face of a resin-embedded biological sample and this often presents challenges and considerations that must be addressed. The accumulation of electrons within the block during imaging, known as "tissue charging," can lead to a loss of contrast and an inability to appreciate cellular structure. Moreover, while increasing electron beam intensity/voltage or decreasing beam-scanning speed can increase image resolution, this can also have the unfortunate side effect of damaging the resin block and distorting subsequent images in the imaging series. Here we present a routine protocol for the preparation of biological tissue samples that preserves cellular ultrastructure and diminishes tissue charging. We also provide imaging considerations for the rapid acquisition of high-quality serial-images with minimal damage to the tissue block.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microscopia Eletrônica de Varredura / Face Limite: Animals Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microscopia Eletrônica de Varredura / Face Limite: Animals Idioma: En Ano de publicação: 2021 Tipo de documento: Article