Your browser doesn't support javascript.
loading
Left ventricular myocardial function in hemodialysis patients: the effects of preload decrease in conventional, Doppler and speckle tracking echocardiography parameters.
Charfeddine, Salma; Abid, Leila; Hammami, Rania; Bahloul, Amine; Triki, Faten; Kammoun, Samir.
Afiliação
  • Charfeddine S; Department of Cardiology, Hedi Chaker University Hospital, Sfax, Tunisia.
  • Abid L; Department of Cardiology, Hedi Chaker University Hospital, Sfax, Tunisia.
  • Hammami R; Department of Cardiology, Hedi Chaker University Hospital, Sfax, Tunisia.
  • Bahloul A; Department of Cardiology, Hedi Chaker University Hospital, Sfax, Tunisia.
  • Triki F; Department of Cardiology, Hedi Chaker University Hospital, Sfax, Tunisia.
  • Kammoun S; Department of Cardiology, Hedi Chaker University Hospital, Sfax, Tunisia.
Pan Afr Med J ; 38: 45, 2021.
Article em En | MEDLINE | ID: mdl-33854674
ABSTRACT

INTRODUCTION:

our aim was to investigate the value of conventional echocardiography, pulsed Doppler and speckle tracking imaging (STI) analysis in the assessment of the left ventricular (LV) myocardial function in hemodialysis (HD) patients with preserved LV ejection fraction and to evaluate the effect of a single HD session on the LV systolic and diastolic functions.

METHODS:

the study population consisted of 30 chronic HD patients. Echocardiography and Doppler studies were performed before and after HD. The LV global longitudinal, circumferential and radial strains were measured with two and three-dimensional STI.

RESULTS:

after HD, LV dimensions, left atrium (LA) area, systolic pulmonary arterial pressure and inferior vena cava diameter decreased significantly. The peak mitral E velocity, the E/A ratio of the mitral inflow and the lateral E/E´ ratio decreased also significantly. The LV and LA volumes index and LV mass index (LVMi) decreased remarkably after HD. The 3D- LV and LA ejection fractions were unchanged after HD. Although, 3D-estimated LVEF seemed to be preserved in the HD patients, the 2D and 3D- strain rates were decreased in all directions. The global strain values improved in all directions after a single HD session. Inverse correlations were found between the LVMi, serum BNP and LV global longitudinal strain.

CONCLUSION:

in HD patients with preserved LV ejection fraction, the STI analysis may add important information concerning the subclinical LV dysfunction.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ecocardiografia / Função Ventricular Esquerda / Diálise Renal / Disfunção Ventricular Esquerda Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ecocardiografia / Função Ventricular Esquerda / Diálise Renal / Disfunção Ventricular Esquerda Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article