Your browser doesn't support javascript.
loading
The in vivo QTc core assay: An evaluation of QTc variability, detection sensitivity and implications for the improvement of conscious dog and non-human primate telemetry studies.
Baublits, Joel; Vargas, Hugo M; Engwall, Michael J.
Afiliação
  • Baublits J; Amgen Research, Translational Safety & Bioanalytical Sciences, Thousand Oaks, CA, USA. Electronic address: jbaublit@amgen.com.
  • Vargas HM; Amgen Research, Translational Safety & Bioanalytical Sciences, Thousand Oaks, CA, USA.
  • Engwall MJ; Amgen Research, Translational Safety & Bioanalytical Sciences, Thousand Oaks, CA, USA.
J Pharmacol Toxicol Methods ; 109: 107067, 2021.
Article em En | MEDLINE | ID: mdl-33857614
ABSTRACT
The ICH S7B guideline describes the requirement to conduct an in vitro IKr (hERG) and in vivo QTc assay for human risk assessment of new drug products, but the guidance is devoid of recommendations on study execution or quality. In the absence of standard practice, multiple study designs and experimental approaches have been utilized, especially with the nonclinical QTc assay. Since 2009, our approach to the in vivo QTc assay has been consistent for small molecules and yields reproducible and sensitive levels for QTc signal detection. Our database and experience indicate that nonrodent telemetry studies can achieve high sensitivity and a calculated metric of study power can be used to indicate study quality. Using a retrospective statistical power analysis of multiple studies (n = 14 dog; n = 6 NHP), the detection sensitivity for a specific study design (N = 8; double Latin square cross-over) was determined. The output of the power analysis is the minimal detectable effect at 80% power and a 95% probability level. The design provided an average sensitivity to detect a 4.7 (2.0%) and 6.5 (1.9%) msec QTcI change in dog and NHP, respectively. These findings suggest that this experimental approach has a consistent and reproducible sensitivity to enable a robust QTcI risk evaluation and can be used confidently to support an integrated nonclinical-clinical pro-arrhythmia risk assessment. The inclusion of power analysis (i.e., QTc sensitivity) data in a regulatory submission provides key information to critical stakeholders about the quality of the in vivo QTc assessment and its value for human safety testing.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Síndrome do QT Longo Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Risk_factors_studies Limite: Animals Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Síndrome do QT Longo Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Risk_factors_studies Limite: Animals Idioma: En Ano de publicação: 2021 Tipo de documento: Article