A simple and effective method for the accurate extraction of kinetic parameters using differential Tafel plots.
Khadke, Prashant; Tichter, Tim; Boettcher, Tim; Muench, Falk; Ensinger, Wolfgang; Roth, Christina.
Afiliação
  • Khadke P; Faculty of Engineering Sciences, University of Bayreuth, Universitaetsstr.30, 95440, Bayreuth, Germany. prashant.khadke@uni-bayreuth.de.
  • Tichter T; Physical and Theoretical Chemistry, Free University of Berlin, Takustr. 3, 14195, Berlin, Germany.
  • Boettcher T; Department of Materials- and Geoscience, Technische Universitaet Darmstadt, Alarich-Weiss-Str. 2, 64287, Darmstadt, Germany.
  • Muench F; Department of Materials- and Geoscience, Technische Universitaet Darmstadt, Alarich-Weiss-Str. 2, 64287, Darmstadt, Germany.
  • Ensinger W; Department of Materials- and Geoscience, Technische Universitaet Darmstadt, Alarich-Weiss-Str. 2, 64287, Darmstadt, Germany.
  • Roth C; Faculty of Engineering Sciences, University of Bayreuth, Universitaetsstr.30, 95440, Bayreuth, Germany.
Sci Rep ; 11(1): 8974, 2021 Apr 26.
Article em En | MEDLINE | ID: mdl-33903627
ABSTRACT
The practice of estimating the transfer coefficient ([Formula see text]) and the exchange current ([Formula see text]) by arbitrarily placing a straight line on Tafel plots has led to high variance in these parameters between different research groups. Generating Tafel plots by finding kinetic current, [Formula see text] from the conventional mass transfer correction method does not guarantee an accurate estimation of the [Formula see text] and [Formula see text]. This is because a substantial difference in values of [Formula see text] and [Formula see text] can arise from only minor deviations in the calculated values of [Formula see text]. These minor deviations are often not easy to recognise in polarisation curves and Tafel plots. Recalling the IUPAC definition of [Formula see text] , the Tafel plots can be alternatively represented as differential Tafel plots (DTPs) by taking the first order differential of Tafel plots with respect to overpotential. Without further complex processing of the existing raw data, many crucial observations can be made from DTP which is otherwise very difficult to observe from Tafel plots. These for example include a) many perfectly looking experimental linear Tafel plots (R2 > 0.999) can give rise to incorrect kinetic parameters b) substantial differences in values of [Formula see text] and [Formula see text] can arise when the limiting current ([Formula see text]) is just off by 5% while performing the mass transfer correction c) irrespective of the magnitude of the double layer charging current ([Formula see text]), the Tafel plots can still get significantly skewed when the ratio of [Formula see text] is small. Hence, in order to determine accurate values of [Formula see text] and [Formula see text], we show how the DTP approach can be applied to experimental polarisation curves having well defined [Formula see text], poorly defined [Formula see text] and no [Formula see text] at all.