Your browser doesn't support javascript.
loading
An evaluation of the Unyvero pneumonia system for rapid detection of microorganisms and resistance markers of lower respiratory infections-a multicenter prospective study on ICU patients.
Sun, Lingxiao; Li, Lijuan; Du, Sisi; Liu, Yingmei; Cao, Bin.
Afiliação
  • Sun L; National Clinical Research Centre for Respiratory Diseases, China-Japan Friendship Hospital, Capital Medical University, Beijing, China.
  • Li L; Department of Pulmonary and Critical Care Medicine, Centre for Respiratory Diseases, China-Japan Friendship Hospital, Beijing, China.
  • Du S; National Clinical Research Centre for Respiratory Diseases, China-Japan Friendship Hospital, Capital Medical University, Beijing, China.
  • Liu Y; Department of Pulmonary and Critical Care Medicine, Centre for Respiratory Diseases, China-Japan Friendship Hospital, Beijing, China.
  • Cao B; National Clinical Research Centre for Respiratory Diseases, China-Japan Friendship Hospital, Capital Medical University, Beijing, China.
Eur J Clin Microbiol Infect Dis ; 40(10): 2113-2121, 2021 Oct.
Article em En | MEDLINE | ID: mdl-33934275
ABSTRACT
Rapid diagnosis of microorganisms and antibiotic resistance is vital for the appropriate treatment of patients with lower respiratory infections, especially for patients in Intensive Care Unit. We conducted a multicenter prospective study to evaluate the ability of the Unyvero pneumonia system for rapid detection from bronchoalveolar lavage fluid (BALF) in China. Eighty-four patients with lower respiratory infections were enrolled, and their BALF samples were collected, and Unyvero, a rapid molecular diagnostic sample-to-answer solution based on multiple PCRs, was applied to detect 21 types of pathogens and 19 types of resistance markers, compared to a routine bacterial culture method. The overall concordance of Unyvero and routine culture was 69/84 (82.1%). Unyvero detected more microorganisms than routine culture (38.1% vs 27.4%, P<0.05) and reported multi-pathogens in more patients than routine culture (10.7% vs 2.4%, P=0.01). The overall sensitivity and specificity of Unyvero for bacteria detection were 84.0% and 98.0%. Besides, Unyvero showed a good performance for antibiotic-resistant bacteria, except Pseudomonas aeruginosa. The concordance was 87.5-100% for methicillin-resistant Staphylococcus aureus and carbapenem-resistant isolates but was only 20-33.3% for Pseudomonas aeruginosa. The high-level semi-quantitative signal intensity of microorganisms detected positive by Unyvero correlates well with positive bacterial cultures. For specimens that were exposed to antibiotic treatment, the Unyvero pneumonia system showed a high concordance with routine bacterial culture and performs well for the detection of antibiotic-resistant bacteria, especially, carbapenem-resistant Klebsiella pneumoniae. It shows promise in guiding the clinical use of antibiotics, such as ceftazidime/avibactam. However, the system needs improvement in detecting resistance markers of Pseudomonas aeruginosa.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções Respiratórias / Bactérias / Patologia Molecular / Reação em Cadeia da Polimerase Multiplex Tipo de estudo: Clinical_trials / Diagnostic_studies / Evaluation_studies / Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções Respiratórias / Bactérias / Patologia Molecular / Reação em Cadeia da Polimerase Multiplex Tipo de estudo: Clinical_trials / Diagnostic_studies / Evaluation_studies / Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Ano de publicação: 2021 Tipo de documento: Article