Your browser doesn't support javascript.
loading
Strategy for the identification of flavor compounds in e-liquids by correlating the analysis of GCxIMS and GC-MS.
Augustini, Alexander L R M; Sielemann, Stefanie; Telgheder, Ursula.
Afiliação
  • Augustini ALRM; Hamm-Lippstadt University of Applied Sciences, Marker Allee 76-78, 59063, Hamm, Germany; Faculty of Chemistry, Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstrasse 5, 45141, Essen, Germany. Electronic address: alexander.augustini@hshl.de.
  • Sielemann S; Hamm-Lippstadt University of Applied Sciences, Marker Allee 76-78, 59063, Hamm, Germany. Electronic address: stefanie.sielemann@hshl.de.
  • Telgheder U; Faculty of Chemistry, Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstrasse 5, 45141, Essen, Germany. Electronic address: ursula.telgheder@uni-due.de.
Talanta ; 230: 122318, 2021 Aug 01.
Article em En | MEDLINE | ID: mdl-33934782
ABSTRACT
This work presents a strategy to correlate the results from gas chromatography coupled ion mobility spectrometry (GCxIMS) and mass spectrometry (GC-MS) to enable a simpler and cheaper analysis of flavor compounds in e-liquids. The use of the retention index for GCxIMS measurements was validated for its application to correlate results with GC-MS data. The easy detection of the GCxIMS for substances at concentrations as low as 1 µg/L can therefore be combined with the identification power of the MS. The use of the MS' mass signals and wide-spread availability of mass spectra libraries reduces the effort necessary to choose the correct reference standards for the identification of unknown substances. Between both detectors, correlating of the retention time indices was achieved for ± 1%. 2-Alkanones were used as an alternative reference point for the IMS and the well-established alkanes for the MS. The application on flavor compounds in e-liquids shows equal or better results than those presented for more complex, hardware-based correlations like line splitting. Additionally, the inverted reduced mobility combined with the retention index of a non-polar column enables simple extrapolation for the confirmation of expected substances as well as the use in a transferable database. For the first time, this comprehensive application allows an extensive, simplified, and cheap identification of flavor compounds in e-liquids by GCxIMS and GC-MS.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article