Your browser doesn't support javascript.
loading
Immunodiagnosis and molecular validation of Toxoplasma gondii-recombinant dense granular (GRA) 5 protein for the detection of toxoplasmosis in hemodialysis patients.
Arab-Mazar, Zahra; Javadi Mamaghani, Amirreza; Fallahi, Shirzad; Rajaeian, Simin; Koochaki, Ameneh; Seyyed Tabaei, Seyyed Javad; Rezaee, Hanieh.
Afiliação
  • Arab-Mazar Z; Department of Medical Parasitology and Mycology, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
  • Javadi Mamaghani A; Infectious Diseases and Tropical Medicine Research Center, Shahid Beheshti University of Medial Sciences, Tehran, Iran.
  • Fallahi S; Department of Medical Parasitology and Mycology, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Rajaeian S; Razi Herbal Medicines Research Center, Lorestan University of Medical Science, Khorramabad, Iran.
  • Koochaki A; Department of Medical Parasitology and Mycology, Faculty of Medicine, Lorestan University of Medical Sciences, Khorramabad, Iran, Iran.
  • Seyyed Tabaei SJ; Department of Applied Cell Sciences, School of advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran.
  • Rezaee H; Department of Biotechnology, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran.
Semin Dial ; 34(5): 332-337, 2021 09.
Article em En | MEDLINE | ID: mdl-33939858
ABSTRACT
Toxoplasmosis causes serious complications in immunocompromised and pregnant women. Serological tests for the detection of toxoplasmosis are often designed from parasitic tachyzoites antigens. The process of producing these antigens is very difficult. The purpose of this study was evaluation of T. gondii-rGRA5 for the immunodiagnosis and molecular detection of Toxoplasma infection using enzyme-linked immunosorbent assay (ELISA) and LAMP methods in hemodialysis patients. The GRA5 gene was successfully expressed and purified by affinity chromatography assay and evaluated by western blot. Then it was used to design an ELISA assay. A total of 260 samples were tested for anti-Toxoplasma IgG and IgM antibodies using a commercial ELISA kit and designed ELISA kit. Finally, the LAMP method was used to evaluate the precision and reliability of the results obtained by commercial and designed ELISA kits. The consistency of the results of two methods was analyzed using the Kappa coefficient of agreement. The rGRA5 revealed higher immunoreactivity with 1100 dilution of sera from toxoplasmosis patients. The specificity and sensitivity of the assay were 93% and 96%, respectively. According to the Kappa coefficient, there was a substantial correlation between the results of ELISA and LAMP based on rGRA5 (≈98%, p < 0.001). Also it showed that rGRA5 protein can be used as an antigenic protein for designing sero-diagnostic tests to identify Toxoplasma infection especially in hemodialysis patients.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Toxoplasma / Toxoplasmose Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Pregnancy Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Toxoplasma / Toxoplasmose Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Pregnancy Idioma: En Ano de publicação: 2021 Tipo de documento: Article