Your browser doesn't support javascript.
loading
Comparison of 2D and 3D quiescent-interval slice-selective non-contrast MR angiography in patients with peripheral artery disease.
Varga-Szemes, Akos; Aouad, Pascale; Schoepf, U Joseph; Emrich, Tilman; Yacoub, Basel; Todoran, Thomas M; Koktzoglou, Ioannis; Edelman, Robert R.
Afiliação
  • Varga-Szemes A; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, MSC 226, Charleston, SC, 29425, USA. vargaasz@musc.edu.
  • Aouad P; Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA.
  • Schoepf UJ; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, MSC 226, Charleston, SC, 29425, USA.
  • Emrich T; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, MSC 226, Charleston, SC, 29425, USA.
  • Yacoub B; Department of Diagnostic and Interventional Radiology, University Medical Center, Mainz, Germany.
  • Todoran TM; German Center for Cardiovascular Research (DZHK), Partner Site Rhine-Main, Mainz, Germany.
  • Koktzoglou I; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, MSC 226, Charleston, SC, 29425, USA.
  • Edelman RR; Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC, USA.
MAGMA ; 34(5): 649-658, 2021 Oct.
Article em En | MEDLINE | ID: mdl-33963454
ABSTRACT

OBJECTIVE:

To evaluate the potential clinical benefit of the superior spatial resolution of 3D prototype thin-slab stack-of-stars (tsSOS) quiescent-interval slice-selective (QISS) MRA over standard 2D-QISS MRA for the detection peripheral artery disease (PAD), using computed tomography angiography (CTA) as reference. MATERIALS AND

METHODS:

Twenty-three patients (70 ± 8 years, 18 men) with PAD who had previously undergone run-off CTA were prospectively enrolled. Patients underwent non-contrast MRA using 2D-QISS and tsSOS-QISS at 1.5 T. Eighteen arterial segments were evaluated for subjective and objective image quality (normalized signal-to-noise, nSNR), vessel sharpness, and area under the curve (AUC) for > 50% stenosis detection.

RESULTS:

Overall subjective image quality ratings for the entire run-off were not different between tsSOS-QISS and 2D-QISS (3 [3; 4] vs 4 [3; 4], respectively; P = 0.813). Sharpness of primary branch vessels demonstrated improved image quality using tsSOS-QISS compared with 2D-QISS (4 [3; 4] vs 3 [2; 3], P = 0.008). Objective image quality measures were not different between 2D-QISS and tsSOS-QISS (nSNR 5.0 ± 1.9 vs 4.2 ± 1.8; P = 0.132). AUCs for significant stenosis detection by tsSOS-QISS and 2D-QISS were 0.877 and 0.856, respectively (P = 0.336).

DISCUSSION:

The prototype 3D tsSOS-QISS technique provides similar accuracy in patients with PAD to a standard commercially available 2D-QISS technique, indicating that the use of relatively thick slices does not limit the diagnostic performance of 2D-QISS. However, subjective image quality for branch vessel depiction is improved using the 3D approach.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença Arterial Periférica Tipo de estudo: Prognostic_studies Limite: Humans / Male Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença Arterial Periférica Tipo de estudo: Prognostic_studies Limite: Humans / Male Idioma: En Ano de publicação: 2021 Tipo de documento: Article