Clinical analysis of the MyoSure hysteroscopic tissue removal system of endometrial polyps in women with an intact hymen.
BMC Womens Health
; 21(1): 214, 2021 05 22.
Article
em En
| MEDLINE
| ID: mdl-34022866
BACKGROUND: To investigate the clinical efficacy of the MyoSure hysteroscopic tissue removal system in the treatment of endometrial and cervical polyps in women with an intact hymen. METHODS: Retrospective analysis was performed on the clinical data of 32 patients treated with the MyoSure hysteroscopic tissue removal system for endometrial and cervical polyps. RESULTS: All the patients successfully completed the procedure. No intraoperative complications, such as cervical trauma, uterine perforation or TURP syndrome, were reported. The surgical time ranged from 5 to 35 min, with an average time of 19.3 min, and the intraoperative blood loss ranged from 2 to 50 ml with an average blood loss of 10.8 ml. After surgery, all patients were shown to have intact hymens. No residual polyp tissues were observed under the microscope, and abnormal uterine bleeding was relieved. CONCLUSIONS: The MyoSure hysteroscopic tissue removal system can be a safe and effective treatment for endometrial and cervical polyps in women with an intact hymen.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Pólipos
/
Doenças Uterinas
/
Neoplasias Uterinas
Tipo de estudo:
Observational_studies
Limite:
Female
/
Humans
/
Pregnancy
Idioma:
En
Ano de publicação:
2021
Tipo de documento:
Article