Your browser doesn't support javascript.
loading
Highly fluorescent carbon dots from coix seed for the determination of furazolidone and temperature.
Zhang, Shen; Wang, Zixin; Pang, Yating; Jing, Zerong; Li, Zheng; Peng, Fangfang; Zhao, Yiyan; Guo, Yuyu.
Afiliação
  • Zhang S; Department of Chemistry, Taiyuan Normal University, Jinzhong 030619, PR China. Electronic address: zhangs@tynu.edu.cn.
  • Wang Z; Department of Chemistry, Taiyuan Normal University, Jinzhong 030619, PR China.
  • Pang Y; Department of Chemistry, Taiyuan Normal University, Jinzhong 030619, PR China.
  • Jing Z; Department of Chemistry, Taiyuan Normal University, Jinzhong 030619, PR China.
  • Li Z; Department of Physics, Taiyuan Normal University, Jinzhong 030619, PR China.
  • Peng F; Department of Physics, Taiyuan Normal University, Jinzhong 030619, PR China.
  • Zhao Y; Department of Physics, Taiyuan Normal University, Jinzhong 030619, PR China.
  • Guo Y; College of Arts, Taiyuan University of Technology, Taiyuan 030024, Shanxi, PR China. Electronic address: guoyuyu@tyut.edu.cn.
Spectrochim Acta A Mol Biomol Spectrosc ; 260: 119969, 2021 Nov 05.
Article em En | MEDLINE | ID: mdl-34051636
ABSTRACT
In this work, blue emission fluorescent carbon dots (CDs) were fabricated by using the hydrothermal strategy from coix seed for the first time. We found that the prepared CDs possessed many excellent characteristics including excitation-dependent properties, good solubility and strong photostability. The optimal excitation and emission wavelength of CDs were 363 and 435 nm, respectively. Unbelievably, the fluorescence of CDs was selectively and effectively quenched with the addition of furazolidone (Fu). The quenching mechanisms might be assumed to the static quenching and inner filter effect (IFE). Based on this principle, a novel fluorescence probe was developed for the determination of Fu. At the same time, the proposed probe showed excellent sensitivity and selectivity towards Fu with a wide linear range from 0.5 to 100 µM, and the corresponding detection limit was 0.096 µM. Moreover, the CDs also could be applied for the sensing of temperature. The practical application of the CDs for Fu detection in real samples was also confirmed with the satisfactory recoveries changing from 96.6% to 108.5%, which provided huge possibility in the field of medical analysis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coix / Pontos Quânticos Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coix / Pontos Quânticos Idioma: En Ano de publicação: 2021 Tipo de documento: Article