Your browser doesn't support javascript.
loading
The effect of surgeon-controlled variables on construct stiffness in lateral locked plating of distal femoral fractures.
Weaver, Michael J; Chaus, George W; Masoudi, Aidin; Momenzadeh, Kaveh; Mohamadi, Amin; Rodriguez, Edward K; Vrahas, Mark S; Nazarian, Ara.
Afiliação
  • Weaver MJ; Department of Orthopaedic surgery, Brigham and Womens Hospital, 75 Francis Street, MA, 02115, Boston, USA. mjweaver@partners.org.
  • Chaus GW; Frontrange Orthoaedics and Spine, 1610 Dry Creek Drive, CO, 80503, Longmont, USA.
  • Masoudi A; Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Isreal Deconess Medical Center, 330 Brookline Ave, MA, 02215, Boston, USA.
  • Momenzadeh K; Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Isreal Deconess Medical Center, 330 Brookline Ave, MA, 02215, Boston, USA.
  • Mohamadi A; Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Isreal Deconess Medical Center, 330 Brookline Ave, MA, 02215, Boston, USA.
  • Rodriguez EK; Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Isreal Deconess Medical Center, 330 Brookline Ave, MA, 02215, Boston, USA.
  • Vrahas MS; Cedars-Sinai Medical Center, 8700 Beverly Blvd, CA, 90048, Los Angeles, USA.
  • Nazarian A; Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Isreal Deconess Medical Center, 330 Brookline Ave, MA, 02215, Boston, USA.
BMC Musculoskelet Disord ; 22(1): 512, 2021 Jun 04.
Article em En | MEDLINE | ID: mdl-34088275
BACKGROUND: Nonunion following treatment of supracondylar femur fractures with lateral locked plates (LLP) has been reported to be as high as 21 %. Implant related and surgeon-controlled variables have been postulated to contribute to nonunion by modulating fracture-fixation construct stiffness. The purpose of this study is to evaluate the effect of surgeon-controlled factors on stiffness when treating supracondylar femur fractures with LLPs: 1. Does plate length affect construct stiffness given the same plate material, fracture working length and type of screws? 2. Does screw type (bicortical locking versus bicortical nonlocking or unicortical locking) and number of screws affect construct stiffness given the same material, fracture working length, and plate length? 3. Does fracture working length affect construct stiffness given the same plate material, length and type of screws? 4. Does plate material (titanium versus stainless steel) affect construct stiffness given the same fracture working length, plate length, type and number of screws? METHODS: Mechanical study of simulated supracondylar femur fractures treated with LLPs of varying lengths, screw types, fractureworking lenghts, and plate/screw material. Overall construct stiffness was evaluated using an Instron hydraulic testing apparatus. RESULTS: Stiffness was 15 % higher comparing 13-hole to the 5-hole plates (995 N/mm849N vs. /mm, p = 0.003). The use of bicortical nonlocking screws decreased overall construct stiffness by 18 % compared to bicortical locking screws (808 N/mm vs. 995 N/mm, p = 0.0001). The type of screw (unicortical locking vs. bicortical locking) and the number of screws in the diaphysis (3 vs. 10) did not appear to significantly influence construct stiffness (p = 0.76, p = 0.24). Similarly, fracture working length (5.4 cm vs. 9.4 cm, p = 0.24), and implant type (titanium vs. stainless steel, p = 0.12) did also not appear to effect stiffness. DISCUSSION: Using shorter plates and using bicortical nonlocking screws (vs. bicortical locking screws) reduced overall construct stiffness. Using more screws, using unicortical locking screws, increasing fracture working length and varying plate material (titanium vs. stainless steel) does not appear to significantly alter construct stiffness. Surgeons can adjust plate length and screw types to affect overall fracture-fixation construct stiffness; however, the optimal stiffness to promote healing remains unknown.