DiSpect: Displacement spectrum imaging of flow and tissue perfusion using spin-labeling and stimulated echoes.
Magn Reson Med
; 86(5): 2468-2481, 2021 11.
Article
em En
| MEDLINE
| ID: mdl-34096098
ABSTRACT
PURPOSE:
We propose a new method, displacement spectrum (DiSpect) imaging, for probing in vivo complex tissue dynamics such as motion, flow, diffusion, and perfusion. Based on stimulated echoes and image phase, our flexible approach enables observations of the spin dynamics over short (milliseconds) to long (seconds) evolution times.METHODS:
The DiSpect method is a Fourier-encoded variant of displacement encoding with stimulated echoes, which encodes bulk displacement of spins that occurs between tagging and imaging in the image phase. However, this method fails to capture partial volume effects as well as blood flow. The DiSpect variant mitigates this by performing multiple scans with increasing displacement-encoding steps. Fourier analysis can then resolve the multidimensional spectrum of displacements that spins exhibit over the mixing time. In addition, repeated imaging following tagging can capture dynamic displacement spectra with increasing mixing times.RESULTS:
We demonstrate properties of DiSpect MRI using flow phantom experiments as well as in vivo brain scans. Specifically, the ability of DiSpect to perform retrospective vessel-selective perfusion imaging at multiple mixing times is highlighted.CONCLUSION:
The DiSpect variant is a new tool in the arsenal of MRI techniques for probing complex tissue dynamics. The flexibility and the rich information it provides open the possibility of alternative ways to quantitatively measure numerous complex spin dynamics, such as flow and perfusion within a single exam.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Imageamento por Ressonância Magnética
Tipo de estudo:
Observational_studies
Idioma:
En
Ano de publicação:
2021
Tipo de documento:
Article