Your browser doesn't support javascript.
loading
Immobilization of Molecularly Imprinted Polymer Nanoparticles onto Surfaces Using Different Strategies: Evaluating the Influence of the Functionalized Interface on the Performance of a Thermal Assay for the Detection of the Cardiac Biomarker Troponin I.
McClements, Jake; Seumo Tchekwagep, Patrick Marcel; Vilela Strapazon, Ana Luiza; Canfarotta, Francesco; Thomson, Alan; Czulak, Joanna; Johnson, Rhiannon E; Novakovic, Katarina; Losada-Pérez, Patricia; Zaman, Azfar; Spyridopoulos, Ioakim; Crapnell, Robert D; Banks, Craig E; Peeters, Marloes.
Afiliação
  • McClements J; School of Engineering, Newcastle University, Merz Court, Claremont Road, NE1 7RU Newcastle upon Tyne, U.K.
  • Seumo Tchekwagep PM; School of Engineering, Newcastle University, Merz Court, Claremont Road, NE1 7RU Newcastle upon Tyne, U.K.
  • Vilela Strapazon AL; Analytical Chemistry Laboratory, Faculty of Science, University of Yaoundé I, 812 Yaoundé Cameroon.
  • Canfarotta F; Faculdade de Ciências Farmacêuticas, Universidade de São Paulo, Av. Lineu Prestes, 580, São Paulo, São Paulo 05508-900, Brazil.
  • Thomson A; MIP Diagnostics Ltd, The Exchange Building, Colworth Park, Sharnbrook, MK44 1LQ Bedford, U.K.
  • Czulak J; MIP Diagnostics Ltd, The Exchange Building, Colworth Park, Sharnbrook, MK44 1LQ Bedford, U.K.
  • Johnson RE; MIP Diagnostics Ltd, The Exchange Building, Colworth Park, Sharnbrook, MK44 1LQ Bedford, U.K.
  • Novakovic K; MIP Diagnostics Ltd, The Exchange Building, Colworth Park, Sharnbrook, MK44 1LQ Bedford, U.K.
  • Losada-Pérez P; School of Engineering, Newcastle University, Merz Court, Claremont Road, NE1 7RU Newcastle upon Tyne, U.K.
  • Zaman A; Experimental Soft Matter and Thermal Physics (EST) Group, Department of Physics, Université Libre de Bruxelles, Boulevard du Triomphe CP223, 1050 Brussels, Belgium.
  • Spyridopoulos I; Department of Cardiology, Freeman Hospital and Newcastle University, Translational and Clinical Research Institute, NE7 7DN Newcastle upon Tyne, U.K.
  • Crapnell RD; Department of Cardiology, Freeman Hospital and Newcastle University, Translational and Clinical Research Institute, NE7 7DN Newcastle upon Tyne, U.K.
  • Banks CE; Faculty of Science and Engineering, Manchester Metropolitan University, John Dalton Building, Chester Street, M1 5GD Manchester, U.K.
  • Peeters M; Faculty of Science and Engineering, Manchester Metropolitan University, John Dalton Building, Chester Street, M1 5GD Manchester, U.K.
ACS Appl Mater Interfaces ; 13(24): 27868-27879, 2021 Jun 23.
Article em En | MEDLINE | ID: mdl-34110781
ABSTRACT
We demonstrate that a novel functionalized interface, where molecularly imprinted polymer nanoparticles (nanoMIPs) are attached to screen-printed graphite electrodes (SPEs), can be utilized for the thermal detection of the cardiac biomarker troponin I (cTnI). The ultrasensitive detection of the unique protein cTnI can be utilized for the early diagnosis of myocardial infraction (i.e., heart attacks), resulting in considerably lower patient mortality and morbidity. Our developed platform presents an innovative route to develop accurate, low-cost, and disposable sensors for the diagnosis of cardiovascular diseases, specifically myocardial infraction. A reproducible and advantageous solid-phase approach was utilized to synthesize high-affinity nanoMIPs (average size = 71 nm) for cTnI, which served as synthetic receptors in a thermal sensing platform. To assess the performance and commercial potential of the sensor platform, various approaches were used to immobilize nanoMIPs onto thermocouples or SPEs dip coating, drop casting, and a covalent approach relying on electrografting with an organic coupling reaction. Characterization of the nanoMIP-functionalized surfaces was performed with electrochemical impedance spectroscopy, atomic force microscopy, and scanning electron microscopy. Measurements from an in-house designed thermal setup revealed that covalent functionalization of nanoMIPs onto SPEs led to the most reproducible sensing capabilities. The proof of application was provided by measuring buffered solutions spiked with cTnI, which demonstrated that through monitoring changes in heat transfer at the solid-liquid interface, we can measure concentrations as low as 10 pg L-1, resulting in the most sensitive test of this type. Furthermore, preliminary data are presented for a prototype platform, which can detect cTnI with shorter measurement times and smaller sample volumes. The excellent sensor performance, versatility of the nanoMIPs, and reproducible and low-cost nature of the SPEs demonstrate that this sensor platform technology has a clear commercial route with high potential to contribute to sustainable healthcare.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Troponina I / Nanopartículas / Polímeros Molecularmente Impressos Tipo de estudo: Diagnostic_studies / Screening_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Troponina I / Nanopartículas / Polímeros Molecularmente Impressos Tipo de estudo: Diagnostic_studies / Screening_studies Idioma: En Ano de publicação: 2021 Tipo de documento: Article