Your browser doesn't support javascript.
loading
Ganglion Cell Complex Parameters in Primary Angle Closure Suspects.
Tang, Yizhen; Pan, Xiaohua; Cao, Kai; Feng, Hui; Yang, Yue; Hu, Zhongyin; Yan, Fancheng; Han, Ying; Li, Shuning.
Afiliação
  • Tang Y; Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
  • Pan X; NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.
  • Cao K; Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China.
  • Feng H; Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China, katepan1212@163.com.
  • Yang Y; Beijing Institute of Ophthalmology, Capital Medical University, Beijing, China.
  • Hu Z; Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China.
  • Yan F; Department of Ophthalmology, The Third Hospital of Mianyang, Sichuan Mental Health Center, Mianyang, China.
  • Han Y; Department of Ophthalmology, First People's Hospital of Yunnan Province, Kunming, China.
  • Li S; Department of Ophthalmology, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
Ophthalmic Res ; 64(5): 844-850, 2021.
Article em En | MEDLINE | ID: mdl-34139705
ABSTRACT

INTRODUCTION:

This study aimed to investigate the ganglion cell complex (GCC) parameters in primary angle closure suspects (PACS) and identify the related factors.

METHODS:

A total of 731 subjects, including 289 subjects with PACS and 442 subjects without PACS, underwent RTVue XR OCT. GCC parameters were compared between the two groups. The linear mixed-effects model was performed to evaluate the relationships between the GCC parameters and related factors.

RESULTS:

Significant differences were found in gender, age, spherical refractive error, height, waist, anterior chamber depth, lens thickness, axial length, superior GCC thickness, ganglion cell complex focal loss volume, ganglion cell complex global loss volume, and ganglion cell complex root mean square between PACS and normal controls. The linear mixed-effects model showed that age (p = 0.008) and blood glucose (p = 0.001) were negatively correlated with average GCC thickness in PACS subjects, and PACS (p = 0.036) and age (p < 0.001) were the key influencing factors for average GCC thickness.

CONCLUSION:

GCC parameters in PACS subjects are different from those in normal controls. Careful explanation should be considered when evaluating changes of GCC parameters in patients with PACD.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Células Ganglionares da Retina Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Células Ganglionares da Retina Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article