Your browser doesn't support javascript.
loading
Meeting the new joint British Society of Gastrointestinal and Abdominal Radiology and Royal College of Radiologists CT colonography standards: a 6-year experience.
Duxbury, O; Burling, D; Muckian, J; Lung, P; Obaro, A; Smith, K; Plumb, A.
Afiliação
  • Duxbury O; Intestinal Imaging Centre, St Mark's Hospital, Harrow, UK.
  • Burling D; Intestinal Imaging Centre, St Mark's Hospital, Harrow, UK. Electronic address: dburling@nhs.net.
  • Muckian J; Intestinal Imaging Centre, St Mark's Hospital, Harrow, UK.
  • Lung P; Intestinal Imaging Centre, St Mark's Hospital, Harrow, UK.
  • Obaro A; Intestinal Imaging Centre, St Mark's Hospital, Harrow, UK; Centre for Medical Imaging, University College London, London, UK.
  • Smith K; Intestinal Imaging Centre, St Mark's Hospital, Harrow, UK.
  • Plumb A; Centre for Medical Imaging, University College London, London, UK.
Clin Radiol ; 76(9): 665-673, 2021 Sep.
Article em En | MEDLINE | ID: mdl-34148642
ABSTRACT

AIM:

To audit the performance of computed tomography colonography (CTC) at St Mark's Hospital against the joint British Society of Gastrointestinal and Abdominal Radiology (BSGAR) and Royal College of Radiologists (RCR) standards. MATERIALS AND

METHODS:

A retrospective audit of all CTC studies between January 2012 to December 2017 was performed against the BSGAR/RCR standards along with additional data outwith the guidelines. Evidence was obtained from a central database, radiology information systems (RISs), picture archiving and communication systems (PACSs), and electronic patient records (EPRs).

RESULTS:

Over the 6 years, 13,143 CTCs were performed and 12,996 (99%) were adequate or better. Of the cases 1,867 had a >6 mm polyp or cancer reported (polyp identification rate [PIR] 14%) and the positive predictive value (PPV) was 93% (1,148/1,240). Median radiation dose was 458 mGy·cm, mean additional acquisition rate was 19% (2,505/13,143), subsequent endoscopy rate was 9% (1,222/13,143) and mean interpretation time for a negative study was 34.6 minutes. Nine perforations occurred (perforation rate of 0.068%) and one was symptomatic (symptomatic perforation rate of 0.008%). For suspected cancers, the same-day endoscopy rate was 27% (96/360) and same-day staging rate was 76% (272/360). Post-imaging colorectal cancer rates (PICRC) was 3.06 per 100 cancers detected and 0.23 per 1,000 CTCs. The service was always rated "good" or higher by patients.

CONCLUSION:

This audit shows the CTC service at St Mark's Hospital to be safe and of sufficiently high quality to meet the BSGAR/RCR standards with most outcomes equal to or above the aspirational target. Areas for service and individual reader improvement were also identified.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Colorretais / Fidelidade a Diretrizes / Colonografia Tomográfica Computadorizada Tipo de estudo: Observational_studies / Prognostic_studies Limite: Humans País/Região como assunto: Europa Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Colorretais / Fidelidade a Diretrizes / Colonografia Tomográfica Computadorizada Tipo de estudo: Observational_studies / Prognostic_studies Limite: Humans País/Região como assunto: Europa Idioma: En Ano de publicação: 2021 Tipo de documento: Article